Mayr ROBA 059.500.2 Скачать руководство пользователя страница 4

Installation and Operational Instructions for

 

ROBA

®

-brake-checker AC Type 059.500.2 

(B.0595002.EN)

your reliable partner

27/06/2019 HH/GF/GC 

Page 4 of 8

Chr. Mayr GmbH + Co. KG
Eichenstraße 1, D-87665 Mauerstetten, Germany
Tel.: +49 8341 804-0, Fax: +49 8341 804-421

www.mayr.com

, E-Mail: 

[email protected]

44

Preventative function monitoring

Through the monitoring of different parameters, the ROBA

®

-brake-checker recognises safety critical operating conditions of the 

brake in advance, as well as acute faults (e.g. line breakage). These are determined as they occur and are notified to the user 
as a warning before the brake can no longer be operated. 

Only the mechanical switching function is checked. Conclusions on the braking torque are not possible (e.g. reduced friction 
value due to oiling of the brake lining)

Possible causes for the warning:

•  Increasing wear
•  Rising coil temperature
•  Falling supply voltage
•  Line voltage drop on feed lines to the brake

Technical Data

Size 20

Supply voltage control 
terminal

SELV/PELV 

ripple 

content ≤5 %

U

I

[VDC]

24

(7 - 30)

Coil current

max.

I

max

[A]

3.5

at ≤45 °C

I

RMS

[A]

3.5

at ≤60 °C

I

RMS

[A]

3

at ≤70 °C

I

RMS

[A]

3

Device fuses

Control terminal

Fuse 315 mA, slow acting

Power terminal

Max. 4 A circuit breaker, characteristic K/Z 

(rated brake current)

Protection

IP20

Terminals

Control terminal

Nominal cross-section 0.34 – 2.5 mm² (22 – 14 AWG)

Tightening torque, screws: 0.5 – 0.6 Nm/3.6 lb-in

Power terminal

Nominal cross-section 0.14 – 2.5 mm² (30 – 12 AWG)

Tightening torque, screws: 0.5 – 0.6 Nm/5 - 7 lb-in

Device ambient temperature 

[°C]

-25 to +70 /  -25 to +60

Storage temperature

[°C]

-40 to +105

Conformity markings
Protection

IP20

Installation conditions

The installation position can be user-defined. 

Please ensure sufficient heat dissipation and air convection! 

Do not install near to sources of intense heat!

Size

Type

Input voltage 

± 10% 

 [VDC]

Brake nominal voltage 

[VDC]

Article number

20

059.500.2

max. 207

104

8259978

059.500.2

max. 432 / 320 

1)

207 / 180

8260167

059.500.2 SO 

2)

max. 207

8261306

1) CSA-C22.2 No. 14
2) Customer specific designs

 

 

 

 

 

 

44

Содержание ROBA 059.500.2

Страница 1: ...ectromagnetic fields Guidelines on the Machinery Directive 2006 42 EC The product is a component for installation into machines according to the Machinery Directive 2006 42 EC The product can fulfil t...

Страница 2: ...hort circuits and earth short circuits at the terminals Electronic devices cannot be guaranteed During the risk assessment required when designing the ma chine or system the dangers involved must be e...

Страница 3: ...rectifiers or to fast acting rectifiers based on half wave or bridge rectification which are supplied with alternating voltage 50 60 Hz The module is switched between the rectifier and the brake and...

Страница 4: ...rop on feed lines to the brake Technical Data Size 20 Supply voltage control terminal SELV PELV ripple content 5 UI VDC 24 7 30 Coil current max Imax A 3 5 at 45 C IRMS A 3 5 at 60 C IRMS A 3 at 70 C...

Страница 5: ...ltage 0 VDC 6 Output voltage 7 Output voltage 8 Input voltage 104 432 VDC Wiring Example Outputs Signal 3 0 VDC low Brake is not energised movement of the armature disk for closing the brake 24 VDC hi...

Страница 6: ...lectrical control cabinets and terminal boxes Using them for any other purpose is not allowed Frequency Change 50 60 Hz After a frequency change in the input voltage the switching on process energisat...

Страница 7: ...595002 EN your reliable partner 27 06 2019 HH GF GC Page 7 of 8 Chr Mayr GmbH Co KG Eichenstra e 1 D 87665 Mauerstetten Germany Tel 49 8341 804 0 Fax 49 8341 804 421 www mayr com E Mail info mayr com...

Страница 8: ...clean the brake check the air gap Replace the brake if necessary Correct input voltage polarity Check input voltage and rotate if necessary Error continuous signal Brake release is not recognised Brak...

Отзывы: