Power supply (optional)
1.
Press the flexible connecting rubber lead (certified approval for outdoor use necessary)
through the cable gland and tighten the nut so that the rubber is narrowed and tension
relief is provided.
2.
The connection of ground cable and power supply for the parasol must be absolutely
waterproof. The ground cable (for heavy current: min. 5-pole, min. 4mm², cable cross
section) must be laid to suit the electric load and the length of the lead wire by a qualified
electrician.
Electric installation work should be carried out solely by a certified
electrician. Disregarding this warning may result in serious personal
injuries.
Personal injury in case of faults.
Secure the parasol with an FI fuse or a 30mA RCBO protective switch,
respectively.
According to law, the functioning of protective switches must be checked at
least every six months.
Danger of short circuit.
Water in the plug connector can lead to a short circuit. Protect the connector against
any water.
Make sure that the plug connector remains above the ground when the
parasol is erected
Seal the connector with silicon.
cable gland
flexible rubber lead