background image

4

Overview of the Device 

Handlebars

Pulse sensors

Seat 

Pedal

Cockpit

Tablet holder

Handlebar Shaft

Stand with Transport Rollers 

Stand with 
transport handle

Содержание RunMAXX 90 PRO

Страница 1: ...ENG MAXXUS 90 PRO Bike I N S TA L L AT I O N O P E R AT I N G M A N U A L...

Страница 2: ...ploded Drawing 26 Spare Parts List 27 29 Warranty 30 31 Service Contract 2019 MAXXUS Group GmbH Co KG All rights reserved All rights reserved This publication may not be reproduced stored in a retriev...

Страница 3: ...n ground both in operation and at rest Any uneven surfaces must be removed or made good It is recommended permanently to place a MAXXUS Floor Protection Mat under the device to protect damageable oors...

Страница 4: ...4 Overview of the Device Handlebars Pulse sensors Seat Pedal Cockpit Tablet holder Handlebar Shaft Stand with Transport Rollers Stand with transport handle...

Страница 5: ...16 Hexagon socket screw M10x110 2 pieces Part 15 Grub screw M12x70 2 pieces Part 30 Washer 10 6 pieces Part 11 Hexagon socket screw M8x20 3 pieces Part 31 Spring washer 8 3 pieces Part 20 Phillips sc...

Страница 6: ...structions for the individual assembly steps The installation of the training device must be carried out by responsible adults Carry out the installation of your training device with two adults in a l...

Страница 7: ...screws 15 already inserted Attention When inserting and fastening the handlebar stem 2 make absolutely sure that you do not crush or damage the cables Step 4 Mounting the cockpit Connect the cockpit c...

Страница 8: ...s M8x20 11 three spring washers 8 31 and three washers 8 29 Attention When inserting and attaching the handlebar 9 make absolutely sure that you do not crush or damage the cables Step 6 Fitting the ha...

Страница 9: ...eath the saddle on the saddle tube and fix them with two pan head screws M4x10 20 each Step 9 Mounting the pedals Insert the thread of the right pedal 67 into the receptacle of the right pedal arm and...

Страница 10: ...into electricity and used to power the cockpit and the braking system Switching on the cockpit As soon as you start pedalling the cockpit switches on automatically Switching off the cockpit The cockpi...

Страница 11: ...the pedal posi tion so that the right pedal arm is pointing vertically down and the right pedal is at the lowest point of its radius of motion Now sit on the seat and place the heel of your right foo...

Страница 12: ...ing your training device back into operation after a long period of non use make sure that all fasten ings are secure WARNING Before starting cleaning maintenance and or repair work the exerciser must...

Страница 13: ...value in beats per minute When using an optional transmitter chest belt not included displays the current heart rate in beats minute SPEED Current speed in km h Revolutions per minute RPM Speci catio...

Страница 14: ...ing pauses the current training RESET Button for resetting all values to zero Switching on the device Shortly after the pedalling motion is started the instrument panel switches on automatically Switc...

Страница 15: ...TIME appears in the lower display The value 24 00 flashes in the TIME window Now enter the desired training time with the keys Then press the MODE button Step 4 2 Entering the training distance USE LE...

Страница 16: ...press the MODE button Step 3 Entering the user weight USE LEVEL KEYS TO ADJUST WEIGHT appears in the lower display Then WEIGHT 70 appears Now enter your weight with the keys Then press the MODE butto...

Страница 17: ...hen press the MODE button Step 4 Entering the training time USE LEVEL KEYS TO ADJUST TIME appears in the lower display The value 10 00 flashes in the TIME window Now enter the desired training time wi...

Страница 18: ...s displayed in the RPM window Now PRESS START FOR QUICKSTART OR MODE FOR SETUP appears again in the lower display Press the MODE button Step 2 Entering the user age The lower display shows USE LEVEL K...

Страница 19: ...body fat percentage With this type of measurement an electronic pulse is sent through the body via the hand sensors Since body fat is not or only very poorly conductive the percentage of fat in the bo...

Страница 20: ...25 carbohydrate and 5 protein Fat burning target zone 60 to 70 of the maximum heart rate This training zone is suitable for athletes and sports people who aim to lose weight Training in this zone the...

Страница 21: ...everal people If the display of the pulse does not work only in individual cases the device is not defective In this case we recommend the use of a chest belt to achieve a permanently correct pulse di...

Страница 22: ...Do not just get o your training device immediately the training session is nished Like with the warm up stage you should continue for 3 5 minutes at minimum resistance to cool down After training you...

Страница 23: ...most people have training goals such as weight reduction cardiac exercise training improvement of physical con dition stress reduction etc to strive for training intensity to meet these goals should b...

Страница 24: ...properly and in an environmentally sound manner Batteries Re chargeable Batteries if present in the device According to the Batteries Directive you as end user are legally obliged to return all used b...

Страница 25: ...ust the foot stands Check if the screws at the articu lated joint between the pendulum tubes and the pedal arms are tightened securely My feet fall asleep during training The reason for this is often...

Страница 26: ...26 Exploded Drawing...

Страница 27: ...d screw M10x25 1 19 Allen C K S full thread screw M10x45 4 20 Philips pan head full thread screw M4x10 6 21 Phillips C K S sharp full thread screw M5x15 8 22 Phillips countersunk head full thread scre...

Страница 28: ...56 Front stabilizer cover R B11 151 5x154 5x66 2 1 57 Handlebar cover front B11 289x168 5x144 1 58 Handlebar cover rear B11 312x168 5x88 7 1 59 Back cover of outer cover B11 135x71x79 2 1 60 Cover R...

Страница 29: ...wiring L 600mm 1 82 Accumulator E11 L 100 1 83 Console wiring 1 84 Console handle pulse wiring 1 85 Handle pulse wiring B11 L 1000mm 2 86 Handle pulse 133mm 2 87 Battery holder B11 591x154 5x50 1 88...

Страница 30: ...for your training device starts on the date of purchase and applies solely to products which were purchased directly from the MAXXUS Group GmbH Co KG or one of the MAXXUS Group GmbH Co KG direct and a...

Страница 31: ..._____________________________ Tel No _____________________________________________ Mobile No __________________________________________ Fault Description Please enter a short description of the error...

Страница 32: ...Maxxus Group GmbH Co KG Nordring 80 D 64521 Gross Gerau Germany E Mail info maxxus de www maxxus com...

Отзывы: