STEP 5
Using a small drill bit or probe, determine the thickness
of the roof by inserting probe in mounting holes, mark
probe and measure the depth of the insertion. Add
1.9mm to length measured. (This allows for the
thickness of the ceiling flange.) This will be the length of
screw needed. Refer to tables below for length of screws
in the hardware package.
NOTE
: For curved roofs, measure the thickest part of the
roof.
SKYMAXX Model 00-97100i & 00-97110i
SKYMAXX Model 00-97000i & 00-97010i
STEP 6
Insert the ceiling flange into the opening, lining up the
flanges.
STEP 7
Referring to the screw lengths in the table of STEP 5,
use the proper length screws depending on your roof
thickness to secure the ceiling flange to the rooftop
flange, taking care not to overtighten the screws to avoid
cracking or deforming the ceiling flange and rooftop
flange.
STEP 8
Optional: Install the screws to secure the ceiling flange
to the caravan ceiling. If the ceiling flange does not lay
flat to the ceiling you may want to install screws to
prevent gapping.
STEP 9
To assemble the Interior Shroud to the Ceiling Flange,
line up the flanges with the channels on the Ceiling
Flange. Secure in place by pressing firmly on the Interior
Shroud. This ensures that the clips on the Interior
Shroud will engage the channels on the Ceiling Flange
to lock it in place.
This completes the installation of the
MAXXAIR SKYMAXX ROOFLIGHT
THICKNESS
LENGTH OF
SCREW
23
– 25 mm
26 mm
28
– 30 mm
30 mm
32
– 35 mm
35 mm
38
– 40 mm
40 mm
42 mm
45 mm
THICKNESS
LENGTH OF
SCREW
42 mm
45 mm
46
– 48 mm
48 mm
50
– 52 mm
52 mm
54
– 56 mm
48 mm
58 - 60 mm
60 mm