background image

 

 



 

Problem 

(continued)

 

 
 
 
 
B.  Back of unit 
 
 
 
 
 
 
 
 
 
 
2. Found water on floor after 
overnight shut off. 
 
 
 
 
 
 
 
 
 
3.  Foul odor from fan 
 A.  New Unit . . .  
 
     
 
 
 
 B.  After normal use . . . 
 
 
 
 
4.  No water running over the                 
pads . . .  
 

 

 

 

 

 

 

 

 

 

 

 

5. Scale build-up on cooling pads. 

 

Cause 

(continued)

 

 
Damage to polyethylene housing. Note: 
Check for possible cracks in the blue 
polyethylene. 
 
Excess water at top or bottom of pads. 
 
 
Damage to blue polyethylene housing. 
 
 
Leaking from bottom of pads. 
 
 
 
 
Excessive water pressure.  
 
 
 
 
Float valve maybe stuck in open position. 
 
 
 
 
 
 
New pad may have a temporary odor (this 
is normal) – you may be smelling the 
thermosetting resin on the new pads  

– it will pass.

 

 
 
Water quality – check your immediate 
environment.  
 
 
 
Check your water flow valve first. 
 
 
 
 
Water supply off at main valve source. 
 
 

 
Pump switch is off. 

 

Water filter may be clogged. 

 

 
 

Hard water with excessive mineral content. 

 

Solution 

(continued)

 

 
Repair as necessary. 
 
 
 
Reduce the water flow with the water control 
valve located on the front of the unit. 
 
Search for leaks and repair as necessary. 
 
 
Push bottom of cooling pads gently inside to 
stop leaking. 
 
 
 
Check you pressure. Max water pressure is 413 
KPA (60 p.s.i.), adjust water supply valve to  
1 ¼ turns or install a water pressure regulator 
found at local hardware store. 
 
Contaminants in water; drain cooler, sump and 
refill. If float remains stuck remove pads and 
examine float for debris or damage. Wash out 
debris and replace float. Continue. 
 
 
 
Drain and refill several times in first week to 
remove thermosetting resin smell. 
Add QC Tablets to reduce smell – and algae. 
 
 
Water should be drained about once a month or 
sooner depending on your specific working 
environment – the water quality and conditions. 
 
 
 
Make sure your water flow valve is open. 
MaxxAir units usually operate at peak 
performance at 1 ¼ turns. 
 
 
Open water valve at supply. You may wish to 
keep this valve open at all times. 
 

 
Turn pump switch on. 

 

Remove the cooling pads see section 6.2. Open 
back of unit – open water filter – pull out filter 
screen and clean. Replace and try again. 

 
 
 
Use Evapo-O-Matic Tablets or add a Water 
Stabilizer at the discharge side of the pump.  
 

Flush water from unit’s water reservoir more 
frequently. 

See section 7.4.

 

 

Содержание EC48D1

Страница 1: ...e for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information You will need this This Manual covers a...

Страница 2: ...uit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate serv...

Страница 3: ...Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Turn on pump 6 2 Adjust water flow 6 3 Turn on fan 6 4 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7 2...

Страница 4: ...Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your MaxxAir portable evaporative cooler takes that same existing air combines it with evaporating wat...

Страница 5: ...hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow valve adjusts the amount of water to the unit Next turn water on and fil...

Страница 6: ...u and your specific environment 6 2 Adjust water flow Your MaxxAir operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned on at 1 turns You must determ...

Страница 7: ...maintenance Depending upon your environment and how often you operate your MaxxAir will depend on how dirty your water gets in the reservoir and how often you will need to clean it If you begin to de...

Страница 8: ...air as necessary Push bottom of cooling pads gently inside to stop leaking Check you pressure Max water pressure is 413 KPA 60 p s i adjust water supply valve to 1 turns or install a water pressure re...

Страница 9: ...n sunlight Drain water reservoir completely and wipe dry Replace dry cooling pads Replace top angle bar to hold pads in place Store MaxxAir in dry clean area and cover to prevent dust build up to have...

Страница 10: ...o perform it obligations under this warranty You should therefore retain you sales slip and attach it to the warranty claim CALL OUR FACTORY FOR REPAIR OR REPLACEMENT PARTS In order to obtain the repa...

Отзывы: