background image

 

 



7.2  Removing the cooling pads 

Before your start, make a note of the direction of the angle of the pads flutes 

(see side 

of pads).

 You must put pads back in correct order for your unit to function 

 

effectively. (Note: Install steep side 45° angle flute to the back of unit.) 

Once the retaining angle bar is removed from the top of your MaxxAir unit, reach to the  

top of the dry cooling pad to the left and gently take hold of the top of the pad and gently  

pull back and slightly down – this action will loosen the pad from the unit. Look at the  

direction of the angle of the pad flutes 

(side of pads

). Remove the cooling pad and proceed  

to the next pad. Then, remove all five cooling pads and gently set in a safe place.  

Note: this is a good time to take the cooling pads outside and run clean water over the pads to remove any accumulated dirt  

and debris. 

Do not use high pressure hose

 – this will damage pads and their ability to function effectively. Make sure the  

pads are thoroughly dry before placing back inside the unit. Full exposure to the sunlight is a good way to dry the pads  

while helping remove mold and mildew. 

 

7.3  Daily maintenance 

15 minutes before quitting time – turn off the water pump and let the fan run 10 – 15 minutes – to dry out the cooling pads 

before leaving. Inspect the cooling pads to make sure they are thoroughly dry (this action helps to reduce mold and mildew) 

when pads are completely dry then turn-off fan. 

 

7.4  Periodic maintenance 

Depending upon your environment and how often you operate your MaxxAir will depend on how dirty your water gets in 

the reservoir and how often you will need to clean it. If you begin to detect an algae smell coming from your unit – it’s time 

to  flush  your  MaxxAir  reservoir  with  fresh  water.  Refer  to  and  follow  the  steps  above  in  7.2  and  you  will  only  need  to 

remove 1 or 2 of the cooling pads from the left side of the unit to gain access to your water reservoir. Take a small sponge 

and clean out your water reservoir with a light cleaner and wipe it down completely and let the unit dry. (You may want to 

use a wet / dry shop vacuum to clean out unit). When unit is clean add an Evap-O-Matic tablet – then replace your cooling 

pads (make sure flutes are facing correct direction) retaining bar and bolts and add fresh, clean water back to the units’ water 

reservoir.  Note:  Adding  Evap-O-Matic  helps  to  reduce  algae,  mold  and  mildew.  You  can  order  more  tablets  by  calling 

1.800.433.1626.   

Note: You may want to remove most of water from water reservoir by attaching a garden hose to the drain valve and place 

the end of the garden hose into a drain then, running pump until sump is dry – shutting off pump immediately.  

Warning! Do not run pump without water in the reservoir.

 This action will burn up your MaxxAir’s water pump. 

 

7.5 MaxxAir Trouble Shooting Guide 

 

Problem                                       

 
1.  Water on the Floor 
A.  Front of unit . . . 
       
 
 
 
 

 

Cause

 

 
 
Too much water. 
 
 
 
 
 

 

Solution

 

 
 
Reduce the water flow with the water control 
valve located on the front of the unit. Note: 
Close the valve all the way – then open 1 ¼ 
turns. (MaxxAir units usually operate at peak 
performance at 1 ¼ turns). 
 

 

Содержание EC48D1

Страница 1: ...e for future reference It contains operating procedures maintenance procedures trouble shooting guide replacement parts guide order form and contact information You will need this This Manual covers a...

Страница 2: ...uit is strongly recommended WARNING Check your units electric power cord for insulation breaks cracks or fraying If any of these conditions are found DO NOT USE See your distributor for immediate serv...

Страница 3: ...Turn on pump 5 3 Adjust water flow 5 4 Turn on Fan 6 0 Daily Operating procedures 6 1 Turn on pump 6 2 Adjust water flow 6 3 Turn on fan 6 4 Turn off unit 7 0 Maintenance 7 1 Access inside of unit 7 2...

Страница 4: ...Cooling Works Keeping in mind that regular fans only circulate same temperature air same humidity your MaxxAir portable evaporative cooler takes that same existing air combines it with evaporating wat...

Страница 5: ...hose is connected open the water flow valve located on the front of your unit only one and quarter 1 1 4 turns This water flow valve adjusts the amount of water to the unit Next turn water on and fil...

Страница 6: ...u and your specific environment 6 2 Adjust water flow Your MaxxAir operates most efficiently and maintains uniform cooling pad wetness with the water control valve turned on at 1 turns You must determ...

Страница 7: ...maintenance Depending upon your environment and how often you operate your MaxxAir will depend on how dirty your water gets in the reservoir and how often you will need to clean it If you begin to de...

Страница 8: ...air as necessary Push bottom of cooling pads gently inside to stop leaking Check you pressure Max water pressure is 413 KPA 60 p s i adjust water supply valve to 1 turns or install a water pressure re...

Страница 9: ...n sunlight Drain water reservoir completely and wipe dry Replace dry cooling pads Replace top angle bar to hold pads in place Store MaxxAir in dry clean area and cover to prevent dust build up to have...

Страница 10: ...o perform it obligations under this warranty You should therefore retain you sales slip and attach it to the warranty claim CALL OUR FACTORY FOR REPAIR OR REPLACEMENT PARTS In order to obtain the repa...