general
Environmental
parameters
600V CAT III. and 1000V
CAT II.
Altitude factor
<2000 m
Operating
temperature 0ºC - 40ºC (<80% humidity)
Storage
temperature
-10ºC - 60ºC (<70%
humidity)
Temperature
factor
0,1 x
(determined accuracy)/
ºC (<18ºC or >28ºC)
Maximum
voltage
between the
connectors and
the grounding
600V AC rms or 600V DC
Fuse
µAmA - F 500mA/250V
Ø5x20
Sampling rate
3x/sec
Display
4 digit
Range
selection
automatic and manual
Overload signal
„OL” on the screen
Low battery
signal
„ ” on the screen
Polarity display
„ - „ automatically appears
on the screen
Automatic
power off
If you do not use the device
for 15 minutes, it powers
off automatically. 1 minute
before powering off the
device beeps, and again
when it turns off.
Power
3x1,5 V AAA batteries
Dimensions
156 x 82 x 29 mm
Weight
220g (with batteries)
Accessories
user manual, measuring
wires, carrying case, "K"
type temperature sensor
measuring specifications - accuracy
The below values measured in different ranges
are the exact values that the device guarantees
within 1-2 years of proper usage, within 18ºC-
28ºC operating temperature and 80% relative
humidity. Accuracy is displayed: ± (% read
n number of lower values)
non-contact aC voltage detector
Sensitivity
Frequency
Distance
> 50 V
50 Hz
<150 mm
dC voltage
Range
Resolution
Accuracy
400mV
0,1mV
±(0,8% + 3)
4V
1mV
40V
10mV
400V
100mV
1000V
1V
±(1,0% + 3)
Inward impedance
10MΩ
aC voltage
Range
Resolution
Accuracy
4V
1mV
±(1,0% + 3)
40V
10mV
400V
100mV
750V
1V
±(1,2% + 3)
Inward impedance
10MΩ
Inward voltage
750V AC rms.
Frequency
40 Hz - 400Hz
dC current
Range
Resolution
Accuracy
4000µA
1µA
±(1,2% + 3)
400mA
0,1mA
10A
0,01A
±(2,0% + 8)
Overload
protection
F 500mA/250V for μAmA
ranges