ATA Bus Interface and ATA Commands
6-12
Maxtor D740X-6L 20.0/40.0/60.0/80.0GB AT
)(' 6 !-./9,6#-.
The READ CONFIGURATION command displays the configuration of the drive.
Like the SET CONFIGURATION command, this command is secured to prevent
accidentally accessing it. To access the READ CONFIGURATION command, you
must write the pattern shown in Table 6-7 to the Command Block Registers. The first
byte, 01h, is a subcode to the extended command code, F0h.
'(9>
Accessing the READ CONFIGURATION Command
.
In Table 6-7:
Only the value in address 1F2h of the Command Block Registers
is different from the SET CONFIGURATION command.
Registers 1F2h
through 1F5h
must contain the exact values
shown in Table 6-7. These values function as a key. The drive
responds by setting the ABRT bit in the Error register if the key
is not entered correctly.
To select the drive for which the configuration is to be read, set
register 1F6h. For execution of the command to begin, load
register 1F7h with F0h.
A 512-byte data field is associated with the READ CONFIGURATION command.
A 512-byte read sequence sends this data from the drive to the host. The information
in this data field represents the current settings of the configuration parameters. The
format of the READ CONFIGURATION command data field is similar to that for
the data field of the SET CONFIGURATION command, shown in Table 6-8.
However, in the READ CONFIGURATION command, bytes 0 through 31 of the
data field are not KEY information, as they are in the SET CONFIGURATION
command. The drive reads these bytes as Maxtor CONFIGURATION, followed by
eleven spaces. Users can read the configuration into a buffer, then alter the
configuration parameter settings.
#
Sector Count
01h
Read Configuration Subcode
Sector Number FFh
Password
Cylinder Low
FFh
Password
Cylinder High
3Fh
Password
Device/Head
AXh
(Drive 0)
Drive Select
BXh
(Drive 1)
Drive Select
Command
F0h
Extended Command Code
Содержание D740X-6L 20.0 AT
Страница 1: ......
Страница 10: ...Table of Contents ii Maxtor D540X 4K 20 0 40 0 60 0 80 0GB AT...
Страница 14: ...About This Manual 1 4 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Страница 18: ...General Description 2 4 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Страница 38: ...Installation 3 20 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...
Страница 66: ...Basic Principles of Operation 5 17 MaxtorD740X 6L 20 0 40 0 60 0 80 0GB AT...
Страница 88: ...ATA Bus Interface and ATA Commands 6 22 Maxtor D740X 6L 20 0 40 0 60 0 80 0GB AT...