![Maxton EMV10 Скачать руководство пользователя страница 65](http://html1.mh-extra.com/html/maxton/emv10/emv10_manual_1745748065.webp)
1728 Orbit Way - Minden, Nevada 89423 P: 775-782-1700 F: 775-782-1701 [email protected] www.maxtonvalve.com
65
\\SERVER\CATALOG 2019\2019 Catalog Rev 2
Read Instructions:
All Safety, installation, and setup instructions should be read before installing or operating the EMV10 Electronic Motor Valve.
Failure to follow the installation and setup instruction may result in unsatisfactory performance, equipment damage, or physical injury.
1. Service:
There are no user serviceable parts contained herein. Refer all service to qualified service personnel only.
2.
Risk of Electrical Shock:
Do not remove the valve cover except when making adjustments or servicing the valve. Always turn off all electri-
cal power sources before servicing any mechanical part or assembly. Do not place metal objects in contact with the energized Electronic
Control Board at any time.
3.
EMV10 Power Sources
: The EMV10 Electronic Motor Valve uses multiple electrical power sources. Hazardous voltages may be present
even if one source to the EMV10 is secured. Verify all voltage sources to the EMV10 are secured before making repairs.
4.
Wiring:
All wiring should be routed in such a way that it is not likely to be pulled, pinched, stepped on, have objects placed on it, or damaged
in any way.
5.
Retain User Manual:
The user manual should be retained for future reference.
The Maxton
EMV10
Electronic Motor Valve was designed to meet a growing demand for low use limited access (LULA), handicapped and residential
hydraulic elevator applications. The EMV10 combines hydraulic and electronic control to provide excellent ride quality. The EMV10 has all the features
found in a commercial hydraulic control valves plus electronic safety control and adjustments allowing quick set up and easy problem analysis.
FEATURES
Quick set up and less field adjustments required.
Built in pressure and viscosity compensation.
Ride performance is maintained from empty to fully loaded condition.
Acceleration and deceleration are independent of load and oil viscosity.
Regulated contract down speed, up leveling speed and down leveling speed.
Stabilized leveling speed is achieved in a very short distance.
IMPORTANT SAFEGUARDS
INTRODUCTION AND FEATURES
HYDRAULIC CONTROLLER EMV10
B44
EMV10T SHOWN
Содержание EMV10
Страница 4: ...This page intentionally left blank ...
Страница 12: ...This page intentionally left blank ...
Страница 14: ...This page intentionally left blank ...
Страница 24: ...This page intentionally left blank ...
Страница 38: ...This page intentionally left blank ...
Страница 46: ...This page intentionally left blank ...
Страница 50: ...This page intentionally left blank ...
Страница 52: ...This page intentionally left blank ...
Страница 58: ...This page intentionally left blank ...
Страница 68: ...This page intentionally left blank ...
Страница 74: ...This page intentionally left blank ...
Страница 80: ...This page intentionally left blank ...
Страница 94: ...This page intentionally left blank ...