The MaxTech FHX-1200 is a 12-port hub compliant with the IEEE 802.3u
100Base-TX fast ethernet standard. The twelve RJ-45 ports connect workstations
or other devices together on a 100Base-TX fast ethernet network using twisted-
pair cable. An additional crossover port connects this hub to a second hub using
a standard (straight-through) network cable for easy network expansion. The hub
also provides a stackable port for cascading up to 6 hubs (72 nodes). A full set of
LED indicators assist in network troubleshooting.

The package contains the following items:

• Hub

• Stacking cable

• Power cord

• Rack mount kit

• User’s Guide

Section 2 - Installation

2.1 Connecting Workstations to hub

1.

Locating the Hub - Place the hub in a location central to your networked
computers, or within the maximum cable length (328 ft.) to the farthest
computer. The hub may be placed on a table or mounted in a 19-inch rack
with the included mounting kit.

2.

Connecting the Power Cord - Insert the power cord into the hub’s power
connector (See Figure 1). Plug the other end of the power cord into an AC
power outlet. The hub is powered on when this connection is made. The
power switch has been eliminated to reduce the chance that the hub will be
accidentally turned off.

3.

Connecting Workstations - Connect one end of a Catagory 5 twisted-pair
cable into an open port (1 through 12, except the Daisy-Chain port) on the
hub (See Figure 2). Connect the other end of the cable to the computer to be
networked. The length of the cable must be less than 328 feet (100 meters).

The hub installation is complete. If you have more than one hub and need to
daisy-chain or stack the hubs, proceed to Section 2.2. Otherwise, proceed to
Section 3.

Fans

Stackable Ports

Power

Figure 1 Hub connections

Содержание FHX-1200

Страница 1: ...Part MAN092 Rev 1 0 LS100 User s Guide FHX 1200 Twelve Port Stackable Fast Ethernet Hub...

Страница 2: ...this manual has been validated at the time of this manual s production The manufacturer reserves the right to make any changes and improvements in the product described in this manual at any time and...

Страница 3: ...ers or within the maximum cable length 328 ft to the farthest computer The hub may be placed on a table or mounted in a 19 inch rack with the included mounting kit 2 Connecting the Power Cord Insert t...

Страница 4: ...hrough cable 20 feet or less into a regular port 1 through 12 of the first hub and the other end into the daisy chain port of a second hub The maximum number of hubs between any two nodes workstations...

Страница 5: ...Hub is powered on Off Hub is powered off COLLISION Amber Data Collision has occurred FX ON Green 100 Base FX module is installed and ON UTILIZATION Green Indicates bandwidth being used PARTITION Off P...

Страница 6: ...h ports are physically the same port Solution Use either Port 12 or the Daisy chain port Section 5 Specifications Network Standard IEEE 802 3u Ethernet 100Base TX Class I and Class II Repeater Transfe...

Страница 7: ...the unlikely event you experience difficulty in the use of the product or if it does not operate as described we suggest you 1 consult the Troubleshooting sec tion of this guide and 2 consult with yo...

Страница 8: ...ns below to install the 100Base FX module 1 Disconnect the hub from the electrical outlet 2 Place the hub on a flat and steady surface 3 Remove the 4 bracket screws from the 100Base FX port of the sta...

Страница 9: ...nce This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 Class B EN60555 2 1987 Class A prEN55024...

Страница 10: ...name return address and the RMA clearly on the outside of your package 5 Ship the unit prepaid via UPS or the U S Postal Service to the address provided by the technician when you call We recommend th...

Отзывы: