Connecting Hub to Hub

The network can be expanded beyond twelve workstations by connecting two or more
hubs together. There are two methods for expansion: daisy-chaining two hubs using
a twisted pair cable, or stacking up to six hubs using the hub’s stacking connector.

2.2.1 Daisy-chaining hubs

The hub’s twelfth port features an additional cross-over connection to facilitate daisy-
chaining hubs using standard cable. Plug one end of a standard straight-through cable
(20 feet or less) into a regular port (1 through 12) of the first hub, and the other end into
the daisy-chain port of a second hub. The maximum number of hubs between any
two nodes (workstations) is two, therefore, to daisy-chain more than two hubs, link
several hubs to one central hub (refer to Figure 3).

Note: The Daisy-Chain port is port number 12 with a reversed pin-out. The daisy-
chain port and port 12 cannot be used simultaneously.

2.2.2 Stackinging hubs

Up to six hubs may be stacked using the stacking connectors on the back of the hub.

Figure 2 Connecting a workstation

Regular ports

Cross-over ports

Figure 3 Daisy-chaining hubs

SECOND HUB

FIRST HUB

Содержание FHX-1200

Страница 1: ...Part MAN092 Rev 1 0 LS100 User s Guide FHX 1200 Twelve Port Stackable Fast Ethernet Hub...

Страница 2: ...this manual has been validated at the time of this manual s production The manufacturer reserves the right to make any changes and improvements in the product described in this manual at any time and...

Страница 3: ...ers or within the maximum cable length 328 ft to the farthest computer The hub may be placed on a table or mounted in a 19 inch rack with the included mounting kit 2 Connecting the Power Cord Insert t...

Страница 4: ...hrough cable 20 feet or less into a regular port 1 through 12 of the first hub and the other end into the daisy chain port of a second hub The maximum number of hubs between any two nodes workstations...

Страница 5: ...Hub is powered on Off Hub is powered off COLLISION Amber Data Collision has occurred FX ON Green 100 Base FX module is installed and ON UTILIZATION Green Indicates bandwidth being used PARTITION Off P...

Страница 6: ...h ports are physically the same port Solution Use either Port 12 or the Daisy chain port Section 5 Specifications Network Standard IEEE 802 3u Ethernet 100Base TX Class I and Class II Repeater Transfe...

Страница 7: ...the unlikely event you experience difficulty in the use of the product or if it does not operate as described we suggest you 1 consult the Troubleshooting sec tion of this guide and 2 consult with yo...

Страница 8: ...ns below to install the 100Base FX module 1 Disconnect the hub from the electrical outlet 2 Place the hub on a flat and steady surface 3 Remove the 4 bracket screws from the 100Base FX port of the sta...

Страница 9: ...nce This is to certify that this product complies with ISO IEC Guide 22 and EN45014 It conforms to the following specifications EMC EN55022 1988 CISPR 22 1985 Class B EN60555 2 1987 Class A prEN55024...

Страница 10: ...name return address and the RMA clearly on the outside of your package 5 Ship the unit prepaid via UPS or the U S Postal Service to the address provided by the technician when you call We recommend th...

Отзывы: