This manual describes the function, operation and maintenance of the Maxtec Model MaxO2 ME 

oxygen monitor. The MaxO2 ME utilizes the Maxtec Max-550E oxygen sensor and is engineered 

for fast response, maximum reliability and stable performance. The MaxO2 ME is designed 

primarily for continuous monitoring of oxygen levels delivered by medical oxygen delivery 

equipment and respiratory care systems. Adjustable high and low level alarm set points make 

the MaxO2 ME ideal for use in neonatal, anesthesia and respiratory care.

CLASSIFICATION

Protection against electric shock  .........................................................................................II, Type B
Protection against water ................................................................................................................IPX1
Mode of operation ..............................................................................................................Continuous
Sterilization ................................................................................................................... See section 6.1
Flammable anesthetic mixture ...................................................................................See section 8.1
Power specification ...............................................................7.5V(MAX) 

 1.9W.250mA(MAX) 

Product Disposal Instructions: 

The sensor, batteries, and circuit board are not suitable for regular trash dis-

posal. Return sensor to Maxtec for proper disposal or dispose according to local 

guidelines. Follow local guidelines for disposal of other components. There are 

no special considerations for the disposal of the product packaging.

WARRANTY

The MaxO2  ME Monitor is designed for medical oxygen delivery equipment and systems. 

Under normal operating conditions, Maxtec warrants the MaxO2 ME Monitor to be free from 

defects of workmanship or materials for a period of two (2) years from the date of receipt 

from Maxtec, provided that the unit is properly operated and maintained in accordance with 

Maxtec’s operating instructions. Based on Maxtec’s product evaluation, Maxtec's sole obliga-

tion under the foregoing warranty is limited to making replacements, repairs, or issuing credit 

for equipment found to be defective. This warranty extends only to the buyer purchasing the 

equipment directly from Maxtec or through Maxtec's designated distributors and agents as 

new equipment. Maxtec warrants the Max-550E oxygen sensor in the MaxO2 ME Monitor to 

be free from defects in material and workmanship for a period of two (2) years from Maxtec's 

date of shipment in a MaxO2 ME unit. Should a sensor fail prematurely, the replacement sensor 

is warranted for the remainder of the original sensor warranty period. Routine maintenance 

items, such as batteries, are excluded from warranty. Maxtec and any other subsidiaries shall 

not be liable to the purchaser or other persons for incidental or consequential damages or 

equipment that has been subject to abuse, misuse, mis-application, alteration, negligence 

or accident. 

THESE WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, 

EXPRESSED OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE.

NOTE: In order to obtain optimum performance from your MaxO2 ME monitor, all operation 

and maintenance must be performed in accordance with this manual. Please read the manual 

thoroughly before using the monitor and do not attempt any repair or procedure that is not 

described herein. Maxtec cannot warrant any damage resulting from misuse, unauthorized 

repair or improper maintenance of the instrument.

EMC Notice

This equipment uses, generates, and can radiate radio frequency energy. If not installed and 

used in accordance with the instructions in this manual, electromagnetic interference may 

result. The equipment has been tested and found to comply with the limits set forth in IEC 

60601-1-2 for medical products. These limits provide reasonable protection against electromag-

netic interference when operated in the intended use environments described in this manual.

 MRI Notice

This equipment contains electronic and ferrous components, whose operation can be affected 

by intense electromagnetic fields. Do not operate the MaxO2 ME in an MRI environment or 

in the vicinity of high-frequency surgical diathermy equipment, defibrillators, or shortwave 

therapy equipment. Electromagnetic interference could disrupt the operation of the MaxO2 ME.

WARNINGS 

Indicates a potentially hazardous situation which, if not avoided, could result in death or seri-

ous injury.

 

Before use, all individuals who will be using the MaxO2 ME must become thoroughly familiar with 

the information contained in this Operation Manual. Strict adherence to the operating instruc-

tions is necessary for safe effective product performance. This product will perform only as 

designed if installed and operated in accordance with the manufacturer’s operating instructions.

 

This product is not intended as a life-sustaining or life-supporting device.

 

Medical Oxygen should meet the requirements of USP.

 

The Alarm limits can be set to levels that would render them useless for a particular patient's 

clinical condition. Ensure that the delivered oxygen level and flow rate are set to values pre-

scribed by the patient's physician. Also ensure that the high and low alarm limits are set to 

levels such that they will sound if the oxygen level is outside of safe limits. Be sure to review 

and, if necessary, re-set the alarm limits when the patient's clinical condition changes or 

when the patient's physician prescribes a change in oxygen therapy.

 

To avoid explosion,   

DO NOT

 operate the oxygen monitor in the presence of flammable 

anesthetics or in an atmosphere of explosive gases. Operating the oxygen monitor in flam-

mable or explosive atmospheres may result in fire or explosion.

 

Never allow an excess length of cable near the patient’s head or neck, as such could result in 

strangulation. Secure excess cable to the bed rail or suitable object.

 

Never use a MaxO2 ME monitor with a cable that appears worn, cracked or has damaged 

insulation.

 

The oxygen sensors contain a weak acidic solution encapsulated in a plastic housing. Under 

normal operating conditions the solution (electrolyte) is never exposed. In case of a leak or if 

damaged,   

DO NOT

 use the oxygen sensor.

 

Use only genuine Maxtec accessories and replacement parts. Failure to do so may seriously 

impair the monitor’s performance. Repair or alteration of the MaxO2 ME beyond the scope of the 

maintenance instructions or by anyone other than an authorized Maxtec service person could 

cause the product to fail to perform as designed. No modification of this equipment allowed. 

 

Calibrate the MaxO2 ME weekly when in operation and if environmental conditions change 

significantly. (I.e., Temperature, Humidity, Barometric Pressure. Refer to section 2.2 

Calibration of this manual).

 

Use of the MaxO2 ME near devices that generate electrical fields may cause erratic readings.

 

If the MaxO2 ME is ever exposed to liquids (from spills or immersion) or to any other physical 

abuse, turn the instrument OFF, remove batteries and allow to dry completely, then power ON. 

This will allow the unit to go through its self test and make sure everything is operating correctly.

Conforms to:  

AAMI STD ES60601-1, ISO STD 

80601-2-55, IEC STDS 60601-

1-6, 60601-1-8 & 62366 

Certified to:  

CSA STD C22.2 No. 60601-1

Maxtec
2305 South 1070 West
Salt Lake City, Utah 84119
USA

phone: (800) 748.5355
fax: (801) 973.6090
email: [email protected]
web: www.maxtec.com

NOTE:

 The latest edition of this operating manual can be downloaded from our website at 

www.maxtec.com

 EN 

Instructions for Use

Содержание MaxO2ME

Страница 1: ...MaxO2 ME Instructions for Use E N G L I S H R230M01 001 REV H...

Страница 2: ...60601 1 2formedicalproducts Theselimitsprovidereasonableprotectionagainstelectromag netic interference when operated in the intended use environments described in this manual MRI Notice Thisequipment...

Страница 3: ...comes in con tact with infectious agents Gasleaksthatcauseroomairtomixwiththegassamplemaycauseinaccurateoxygenread ings EnsuretheO ringsonthesensorandflowdiverterareinplaceandintactpriortouse DONOTexp...

Страница 4: ...g Oxygen Calibration 7 3 0 OPERATING INSTRUCTIONS 7 3 1 Alarm Setting Procedure 7 3 1 1 Low Alarm Setting 7 3 1 2 High Alarm Setting 8 3 1 3 Smart Alarm Mode 8 3 2 Basic Operation 8 3 3 Alarm Conditio...

Страница 5: ...mponent Identification 1 LOWALARMLED Inalowalarmcondition theyellow LOWALARM LEDwillflashonce every two seconds accompanied by the audio buzzer If the Oxygen level is below 18 the red LOW ALARM LED wi...

Страница 6: ...sensor after calibration may shift the calibra tion point enough to require recalibration CAUTION The flow diverter for the sensor is for use with flowing gases only DO NOT use the diverter when perf...

Страница 7: ...1 Allow adequate time for the sensor to equilibrate to a new ambient temperature 2 When used in a breathing circuit place the sensor upstream of the heater 3 For best results perform the calibration...

Страница 8: ...from the low alarm setting Pressing the Down key will subtract one from the high alarm setting and add one to the low alarm setting In other words the Up Arrow widens the alarm band and the down arro...

Страница 9: ...the new sensor and tighten the cable connector 6 Screw the flow diverter onto the new sensor 7 Wait approximately 20 minutes for the sensor to reach equilibrium 8 Calibrate the new sensor NOTE If the...

Страница 10: ...axtec Certified Service Technician 6 3 Replacing Sensor Cable After extended use or abuse to the sensor cable the cable may begin to wear and lose its ability to properly retract The cable can be remo...

Страница 11: ...or the reading to stabilize before calibration Also note that the monitor may sense that the concentration is changing and an E07 error code will display Sensors come supplied with a flow diverter The...

Страница 12: ...AC mains input lines IEC 61000 4 11 Dip 95 0 5 periods Dip 60 5 periods Dip 30 25 periods Dip 95 5 seconds Recommended separation distances between portable and mobile RF communications equipment and...

Страница 13: ...os amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic si...

Страница 14: ...2305 South 1070 West Salt Lake City Utah 84119 800 748 5355 www maxtec com...

Отзывы: