PC4204CX Outputs
Module Number: PC4204CX #
Module Number: PC4204CX #
Module Number: PC4204CX #
Module Number: PC4204CX #
Module Number: PC4204CX #
I______I______I
(1-16 = XX)
Partition
Output
1 2 3 4 5 6 7 8
Zone
Schedule # Pulse Timer
[000702XX01]
PC4204CX Relay 1
I______I______I I______I______I______I______I______I______I______I______I
I______I______I______I
I______I______I
I______I______I______I
[000702XX02]
PC4204CX Relay 2
I______I______I I______I______I______I______I______I______I______I______I
I______I______I______I
I______I______I
I______I______I______I
[000702XX03]
PC4204CX Relay 3
I______I______I I______I______I______I______I______I______I______I______I
I______I______I______I
I______I______I
I______I______I______I
[000702XX04]
PC4204CX Relay 4
I______I______I I______I______I______I______I______I______I______I______I
I______I______I______I
I______I______I
I______I______I______I
FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause
interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in
Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following
booklet prepared by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S.
Government Printing Office, Washington, D.C. 20402, Stock # 004-000-00345-4.
©2001 Digital Security Controls Ltd.
Toronto, Canada • www
www
www
www
www.dsc.com
.dsc.com
.dsc.com
.dsc.com
.dsc.com
Technical Support: 1-800-387-3630
Printed in Canada 29005814 R003
5. Programming the Module
To access PC4010/4020 programming, enter [*][8] followed by the
Installer’s Code. Each relay output must be programmed. Please see
the control panel
Installation Manual
and
Programming Worksheets
for
a detailed list of output options.
NOTE: Relay 1 must not be programmed if used for Combus power. Ensure
that jumper CON3 is set to “Repower Relay1.”