XCite™ OEM RF Module – Product Manual v1.1 

Interfacing Hardware 

MaxStream, Inc. developed proprietary interface boards (MaxStream Product numbers: XIB-R for 
RS-232/485 interfacing) to facilitate the connection between XCite OEM RF Modules and serial 
devices. Many integrators develop their own interfacing circuitry; others use MaxStream’s 
Interface Boards. In either case, the following sections illustrate how to interface with XCite OEM 
RF Modules by illustrating properties of the MaxStream XIB-R Interface Board.  

XCite Development Kit (RS-232/485/422) 

The XStream Development Kit includes all the hardware and software needed for basic wireless 
connections. 

Table 4.

 

XCite Development Kit contents 

Item 

Qty. 

Description 

Part Number 

Quick Start Guide 

Quickly familiarize users with some of the XCite Module’s most 

important functions. The guide provides step-by-step 

instructions on how to make an RF link and test its ability to 

transport data over varying ranges and conditions. 

MD0009 

CD 

CD includes documentation and configuration software 

M100105 

XCite Module  

(w/ RPSMA antenna port) 

Module comes with fixed RF Data (baud) rates up to 38400 

bps 

XC09 - (…) NSC 

XCite Module  

(w/ attached wire antenna) 

Module comes with fixed RF Data (baud) rates up to 38400 

bps 

XC09 - (…) WNC 

MaxStream Interface Board 

Supplies regulated 5V DC power to module and provides 

signal-level conversion for interfacing with PC RS-232 serial 

ports or RS-485/422 devices 

XIB-R 

RPSMA Antenna 

RPSMA half-wave dipole antenna 

A09-HASM-675 

Serial Loopback Adapter 

Connects to the female RS-232 (DB-9) serial connector of the 

XCite Module and can be used to configure the radio modem 

to function as a repeater (for range testing) 

JD2D3-CDL-A 

NULL Modem Adapter 

(male-to-male) 

Connects to the female RS-232 (DB-9) serial connector of the 

XCite Module and can be used to connect the radio modem to 

another DCE (female DB9) device 

JD2D2-CDN-A 

NULL Modem Adapter 

(female-to-female) 

Used to bypass radios to verify serial cabling is functioning 

properly 

JD3D3-CDN-A 

Male DB-9 to RJ-45 Adapter 

Facilitates adapting a DB-9 Connector to a CAT5 cable  

(female RJ45 to male DB9) 

JE1D2-CDA-A 

Female DB-9 to RJ-45 Adapter 

Facilitates adapting a DB-9 Connector to a CAT5 cable  

(female RJ45 to female DB9) 

JE1D3-CDA-A 

9V AC Power Adapter 

Wall-based transformer with US 2-prong plug JP4P2-9V4-6F 

9V Battery Clip 

Allows Interface Board to be remotely powered by a 9V battery 

JP2P3-C2C-4I 

RS-232 Cable (6’) 

Straight-through serial cable that connects interface board 

(DCE) to a PC (DTE) 

JD2D3-CDS-6F 

MaxStream Interface Board (Part Number: XIB-R) 

The MaxStream Interface board was developed to provide a means of connecting the XCite 
Module to any system having an RS-232 or RS-485/422 connection. Since the XCite Module 
requires signals to enter at CMOS voltages, one of the main functions of the interface board is to 
convert interface signals between CMOS levels (2.85 – 5.50V) and RS-232 levels (-12 - +12V). 
The MaxStream Interface Board includes the following built-in features: 

 

DIP Switch 

 

Configuration Switch 

 

Power Switch 

 

LEDs 

 

DB-9 Connector 

 

Power Connector 

© 2004 MaxStream, Inc., Confidential and Proprietary 

10

Содержание XCite

Страница 1: ...mponents RF Module Configuration Appendices Product Manual v1 1 For XCite OEM RF Module Part Numbers XC09 009 XC09 038 355 South 520 West Suite 180 Lindon UT 84042 Phone 801 765 9885 Fax 801 765 9895...

Страница 2: ...this manual may be transmitted or reproduced in any form or by any means without the written permission of MaxStream Inc XCite is a trademark of MaxStream Inc Technical Support Phone 801 765 9885 Live...

Страница 3: ...umber XIB R 10 RS 232 485 Interface Board Components Features 11 RF Module Configuration 12 Command Parameter Types 12 XCite Commands Parameter Reference 13 Configuration Software 15 X CTU Software 15...

Страница 4: ...the web www maxstream net helpdesk Features Long Range Indoor Urban Range Up to 300 90 m Outdoor RF Line of sight Range Up to 1000 300 m w 2 1 dB dipole antenna Receiver Sensitivity 108 dBm 9600 Baud...

Страница 5: ...rial data entering the XCite Module from the host 5 DI2 I low Request to Send 6 I low Reset Module Parameters 7 DO3 O high Receive RX LED low Asserted during transmission 8 PWR O high PWR Indicates po...

Страница 6: ...C pin 10 Power GND pin 11 Ground DO2 pin 1 Clear to Send The remaining six pins may be used for additional functionality Go to the XCite Advanced Programming Configuration manual for more detailed inf...

Страница 7: ...and B are associated with Figure 4 Table 3 DC Characteristics Vcc 2 85 to 5 50V Symbol Parameter Condition Min Typical Max Units VIL Input Low Voltage All input signals 0 5 0 3 Vcc V VIH Input High Vo...

Страница 8: ...figure below Figure 6 Data Flow in a UART interfaced environment Low asserted signals distinguished with horizontal line over signal name RS 232 and RS 485 422 Data Flow The XCite Module can enable a...

Страница 9: ...ver the air Selectable using BI Number of Bits Parameter Start and stop bits of the UART signal are not transmitted over the air but are regenerated by the receiving module The MaxStream OEM RF Module...

Страница 10: ...dipole antenna A09 HASM 675 Serial Loopback Adapter 1 Connects to the female RS 232 DB 9 serial connector of the XCite Module and can be used to configure the radio modem to function as a repeater for...

Страница 11: ...Power Connector Center positive 5 5 2 1mm Power can also be supplied through Pin 9 of the DB 9 Connector 10a DIP Switch Figure 10 Back View The DIP Switch configures the XCite OEM RF Module to operat...

Страница 12: ...y entering AT Command Mode and sending commands to the module AT Commands are listed in Table 5 AT Commands can be modified using the any of the following means X CTU Software Modem Configuration tab...

Страница 13: ...the RF packet Only radio modems having matching addresses can communicate with each other Range 0 0xFFFF Networking 2 0 HP Channel Select Hopping or Single Frequency channel on which the radio modem...

Страница 14: ...w control is on by default Range 0 1 0 disable 1 enabled Serial Interfacing 1 0 HT Time before Wake up Initializer Set time period of inactivity no serial or RF data is sent or received before a Wake...

Страница 15: ...tware folder of the MaxStream CD and also under the Downloads section of the following web page http www maxstream net helpdesk Using X CTU software In order to use the X CTU software a module assembl...

Страница 16: ...ing Requirements Label Warning WARNING The Original Equipment Manufacturer OEM must ensure that FCC labeling requirements are met This includes a clearly visible label on the outside of the final prod...

Страница 17: ...ss B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates...

Страница 18: ...1dBi Fixed Mobile A09 HBMM P5I 1 2 wave antenna 2 1dBi Fixed Mobile A09 QBMM P5I 1 4 wave antenna 1 9 dBi Fixed Mobile 1 4 wave integrated wire antenna 1 9 dBi Fixed Mobile FCC approved antennas not...

Страница 19: ...t Channel Capacity Hopping Mode 7 hop sequences share 25 frequencies or Single Channel Mode 25 single frequency channels Serial Data Interface CMOS I O Data Rate Software selectable 1200 57600 bps Pow...

Страница 20: ...ARRANTIES EXPRESS OR IMPLIED AND MAXSTREAM SPECIFICALLY DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL MAXSTREAM ITS SUPPLIERS OR LICENSORS BE LIABLE...

Страница 21: ...hnical support is included with every MaxStream Radio Modem sold Please use the following resources for additional support Documentation www maxstream net helpdesk Technical Support Phone 866 765 9885...

Отзывы: