Chapter 6
31
(5)Microscope
(6)Light source
CAUTION :
◎ It is imperative that the protective lens are checked for dirt, dust, or
damage before you use the fiber connector. It will lead to heavy damage if
the laser equipped with dirty or damaged fiber connector.
◎ The use of a dirty fiber connector can result in laser damage, which is
not covered by the Maxphotonics' warranty.
◎ The laser will not be covered by the Maxphotonics' warranty if the buyer
change the laser without permission.
IMPORTANT :
◎ It is imperative that you wear powder-free rubber gloves during this
cleaning procedure! It is hereby stated that damage to the fiber connector
can occur due to mishandling, the use of incorrect cleaning procedures, or
chemicals for cleaning. This is not covered by the Maxphotonics' warranty.
◎ Ethanol concentration should be above 99.5% during cleaning.
2.Operating Procedures
Cleaning and maintaining according to the following procedures:
(1) Switch off the laser power, and place the key switch on position of
''OFF'';
(2)Remove the black outer protective sleeve and leave the white inner
cap on and clean the fiber connector exterior with optical cleaner, wipe it
with a clean optical wipe and dry it with compressed air.
(3)Place fiber connector in the holder of the microscope, remove the
white inner cap from the connector.
(4)Focus the microscope onto the connector surface so that the