STEP 3 - ATTACH OPTIONAL BATTERY BOX & FRAME
TO VEHICLE (IF EQUIPPED) - Continued
FUSED CABLE
(SEE NOTE)
(-) BATTERY CABLE
TO COMMON
GROUND
FUSED CABLE TO PUMP
BOX, 42” LG.
(BATTERY BOX KIT ITEM)
150 AMP
CIRCUIT
BREAKER
CABLE
12” LG.
CABLE
10” LG.
GROUND CABLE TO
PUMP BOX OR COMMON
CHASSIS GROUND, 74” LG.
(BATTERY BOX KIT ITEM)
12 VOLT BATTERY CONNECTIONS
FOR 24 VOLT POWER
FIG. 33-1