PLATFORM WILL NOT RAISE, MOTOR WILL NOT RUN
TROUBLESHOOTING
1.
Check battery voltage at terminal #1
(FIG.
48-1)
. If voltage is less than 12 volts re-
charge battery.
2.
Touch a jumper wire on terminals #1
and #2
(FIG. 48-1)
. If motor runs check
switch, switch connections and white
wire. Correct connections or replace
switch.
3.
Touch heavy jumper cable to terminals #1
and #3
(FIG. 48-1)
.
If motor runs, replace motor solenoid.
If motor does not run, repair or replace
motor.
WIRING CONNECTIONS ON
STARTER SOLENOID
FIG. 48-1
3
2
1
WHITE
WIRE
BATTERY
CABLE
GREEN
WIRE