1
1921 Slauson
A
ve. Santa Fe Springs, CA. 90670 (800) 227-41
16 F
AX (888) 771-7713
43
STEP 10 - REMOVE LOCKING ANGLES & KNUCKLE
BOLTS, CHECK FOR INTERFERENCE - Continued
5.
Lower platform to the ground
(FIG.
43-2)
. Look for any interference be-
tween liftgate and vehicle as platform
is lowered. If the platform lowers with
a “jerking” motion, bleed air from the
hydraulic system by doing the fol-
lowing. Push the control switch to
the
DOWN
position until you hear
air escaping into the hydraulic
fl
uid
reservoir. Then, raise
the platform
(FIG. 43-3)
. Look for any interfer-
ence between liftgate and vehicle as
platform is raised. Repeat step until
there is no air left in the system and
platform lowers smoothly
(FIG. 43-3)
.
4.
Remove
fl
oor jack and hoist
supporting Liftgate
(FIG. 43-1)
.
REMOVING JACK
FIG. 43-1
FLOOR JACK
LOWERING PLATFORM
FIG. 43-2
RAISING PLATFORM
FIG. 43-3
Содержание GPTWR-25