background image

TABLE OF CONTENTS

WARNINGS ........................................................................................................................... 6

SAFETY INSTRUCTIONS .................................................................................................... 7

LIFTGATE TERMINOLOGY .................................................................................................. 8

PERIODIC MAINTENANCE .................................................................................................. 9

PERIODIC MAINTENANCE CHECKS .................................................................................. 9

PREVENTATIVE MAINTENANCE (PM) CHECKLIST ......................................................... 10

CHECKING HYDRAULIC FLUID .........................................................................................11

CHANGING HYDRAULIC FLUID ........................................................................................ 13

PRESSURIZING HYDRAULIC SYSTEM ............................................................................ 15

TORSION BAR REPLACEMENT & ADJUSTMENT............................................................ 16

DECALS .............................................................................................................................. 26

SYSTEM DIAGRAMS ......................................................................................................... 28

PUMP MOTOR & VALVE OPERATION (MANUAL CLOSE) ............................................... 28

PUMP MOTOR & VALVE OPERATION (EQUIPPED WITH HYDRAULIC CLOSER) ......... 29

HYDRAULIC SCHEMATIC (MANUAL CLOSE) .................................................................. 30

HYDRAULIC SCHEMATIC (EQUIPPED WITH HYDRAULIC CLOSER) ............................ 31

ELECTRICAL SCHEMATIC (MANUAL CLOSE)  ................................................................ 32

ELECTRICAL SCHEMATIC (EQUIPPED WITH HYDRAULIC CLOSER) ........................... 33

ELECTRICAL SCHEMATIC - JUMPER HARNESS ASSEMBLY ........................................ 34

ELECTRICAL SCHEMATIC - HOUSING COVER ASSEMBLY (WITHOUT LIGHTS) ......... 35

ELECTRICAL SCHEMATIC  - HOUSING COVER ASSEMBLY (WITH FOUR LIGHTS) .... 36

ELECTRICAL SCHEMATIC - HOUSING COVER ASSEMBLY, FOREIGN VEHICLE  

(WITH 6 LIGHTS ) ............................................................................................................... 37

DMD ELECTRICAL VALUES .............................................................................................. 38

RECOMMENDED BOLT TORQUES .................................................................................. 39

Содержание DMD-22

Страница 1: ...M 16 40 AUGUST 2018 MAXON Lift Corp 2018...

Страница 2: ......

Страница 3: ...cessing All claims for warranty will be denied if paperwork has not been received or claim submitted via Maxon website for processing by MAXON s Warranty Department within 30 days of repair date All c...

Страница 4: ...CLOSE 28 PUMP MOTOR VALVE OPERATION EQUIPPED WITH HYDRAULIC CLOSER 29 HYDRAULIC SCHEMATIC MANUAL CLOSE 30 HYDRAULIC SCHEMATIC EQUIPPED WITH HYDRAULIC CLOSER 31 ELECTRICAL SCHEMATIC MANUAL CLOSE 32 EL...

Страница 5: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 6: ...te keep your feet and any objects clear of the inboard edge of the platform Your feet or objects on the platform can become trapped between the platform and the Liftgate housing cover WARNING Correctl...

Страница 7: ...cals are available from Maxon Customer Service Consider the safety and location of bystanders and location of nearby objects when operating the Liftgate Stand to one side of the platform while operati...

Страница 8: ...FAX 888 771 7713 8 LIFTGATE TERMINOLOGY RUNNER PLATFORM COLUMN HOUSING COVER PLATFORM LATCH POWER UNIT BEHIND COVER UP DOWN CONTROL SWITCH OUTBOARD UP DOWN CONTROL SWITCH INBOARD TRANSIT HOOK MAIN FR...

Страница 9: ...INTENANCE section Check for loose or missing nuts bolts covers roll pins screws and pins Check that all WARNING and instruction decals are in place and legible Check electrical wiring for chaffing and...

Страница 10: ...y Repair Required Corrected 10 Check switches and wiring connections on Liftgate as well as pump inside main housing Also check ground straps Satisfactory Repair Required Corrected 11 Check the gear p...

Страница 11: ...ing the hydraulic fluid reservoir filler cap drain plug and hydraulic lines clean up contaminants that can get in the openings Also protect the openings from accidental contamination Never mix synthet...

Страница 12: ...OMMENDED BRANDS PART NUMBER CHEVRON HIPERSYN 32 KENDALL GOLDEN MV SHELL TELLUS S2 VX 32 EXXONMOBIL UNIVIS N 32 DTE 24 ISO 15 OR MIL H 5606 HYDRAULIC OIL RECOMMENDED BRANDS PART NUMBER CHEVRON FLUID A...

Страница 13: ...l contamination Never mix synthetic fluids with conventional hydraulic fluids Hydraulic system must be purged if the fluids are mixed NOTE Liftgate is shipped with Exxon Univis HVI 13 hydraulic fluid...

Страница 14: ...bed height FIG 14 1 Continue to hold UP DOWN control switch for 30 60 seconds to circulate hydraulic fluid through slave cylinder and reservoir FIG 14 2 Release UP DOWN control switch PLATFORM AT BED...

Страница 15: ...rating Liftgate under certain conditions with air in system could result in damage to lift and load as well as personal injury If lines are opened closed or replaced and if power unit or cylinders are...

Страница 16: ...nder tension When all tension is released from torsion bar s platform can unfold suddenly Any person in the path of opening platform could be injured WARNING FIG 16 1 2 Support platform and flipover e...

Страница 17: ...ADJUSTMENT Continued PERIODIC MAINTENANCE 5 Loosen locking screw from LH torsion bar housing FIG 17 2 LH TORSION BAR HOUSING LOCKING SCREW LH TORSION BAR 4 With platform securely supported remove cove...

Страница 18: ...713 18 7 Remove LH torsion bar FIG 18 2 REMOVING LH TORSION BAR FIG 18 2 LH TORSION BAR TORSION BAR REPLACEMENT ADJUSTMENT Continued REMOVING LH TORSION BAR PIN FIG 18 1 6 Remove LH torsion bar pin FI...

Страница 19: ...LH TORSION BAR 1 Stow platform Refer to Operation Manual for detailed operating instructions 2 On LH runner remove cap screw lock washer and flat washers from torsion bar pin FIG 19 1 Adjust the LH t...

Страница 20: ...is applied to torsion bar FIG 19 1 Once the platform is unfolded it should lay flat FIG 20 1 position 3 If platform does not lay flat decrease tension by removing cap screw lock washer and flat washe...

Страница 21: ...EPLACEMENT ADJUSTMENT Continued 7 With platform securely supported remove cover plate FIG 21 1 REMOVING COVER PLATE FIG 21 1 PLATFORM COVER PLATE TAPPING SCREWS 8 PLACES 8 Loosen locking screw from LH...

Страница 22: ...ard towards center of vehicle FIG 22 1 Approximate adjustment travel should be no more than 10 INCREASING LH TORSION BAR TENSION FIG 22 1 LH TORSION BAR HOUSING STOP BLOCK 0 10 10 Replace and tighten...

Страница 23: ...upport platform and flipover evenly by placing supports under the RH and LH runners FIG 23 1 FIG 23 1 SUPPORT 2 PLACES TORSION BAR REPLACEMENT ADJUSTMENT Continued PERIODIC MAINTENANCE REPLACE RH TORS...

Страница 24: ...RH TORSION BAR 5 On RH runner unbolt the platform and runner pin from RH runner FIG 24 2 Next remove platform and runner pin and platform spacer FIG 24 2 RH TORSION BAR RH RUNNER FIG 24 2 PLATFORM RU...

Страница 25: ...8 Rotate the RH platform and runner pin clockwise to line up the pin holes with the RH runner threaded holes FIG 25 2 FIG 25 2 9 Secure RH platform and runner pin as shown in FIG 25 2 RH PIN WELDMENT...

Страница 26: ...FAMILY OWNED DECAL P N 283445 01 WARNING DECAL P N 298373 01 DECAL C DECAL F OR G DMD 22 ONLY CAPACITY DECAL P N 220388 03 DMD 33 ONLY CAPACITY DECAL P N 220388 02 NOTE Ensure there is no residue dir...

Страница 27: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 27 WARNING DECAL P N 298373 01 DECAL SHEET P N 289192 01 WARNING DECAL P N 299274 01...

Страница 28: ...OR SOLENOID OPERATION LIFTGATE FUNCTION SOLENOID OPERATION MEANS ENERGIZED MOTOR STARTER SWITCH LOWERING VALVE RAISE LOWER REFER TO VALVES SHOWN ON HYDRAULIC SCHEMATIC PUMP MOTOR VALVE OPERATION MANUA...

Страница 29: ...WITH HYDRAULIC CLOSER TABLE 29 1 POWER UNIT FIG 29 1 STARTER SWITCH MOTOR LOWERING VALVE FOLD UNFOLD VALVE ASSEMBLY POWER UNIT MOTOR VALVE OPERATION LIFTGATE FUNCTION REMOTE VALVE OPERATION MEANS ENER...

Страница 30: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 30 HYDRAULIC SCHEMATIC MANUAL CLOSE FIG 30 1 3 0...

Страница 31: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 31 HYDRAULIC SCHEMATIC EQUIPPED WITH HYDRAULIC CLOSER FIG 31 1 3 0...

Страница 32: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 32 ELECTRICAL SCHEMATIC MANUAL CLOSE FIG 32 1...

Страница 33: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 33 ELECTRICAL SCHEMATIC EQUIPPED WITH HYDRAULIC CLOSER FIG 33 1...

Страница 34: ...TERMINAL F LH STOP TURN TERMINAL E RH STOP TURN TERMINAL E RH STOP TURN TERMINAL D STOP TERMINAL D STOP TERMINAL C REVERSE TERMINAL C REVERSE TERMINAL B TAIL TERMINAL B TAIL TERMINAL A GROUND TERMINA...

Страница 35: ...Springs CA 90670 800 227 4116 FAX 888 771 7713 35 ELECTRICAL SCHEMATIC HOUSING COVER ASSEMBLY WITHOUT LIGHTS SYSTEM DIAGRAMS CONNECT TO WIRING HARNESS LICENSE PLATE LIGHT LH LICENSE PLATE LIGHT RH LI...

Страница 36: ...11921 Slauson Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 36 ELECTRICAL SCHEMATIC HOUSING COVER ASSEMBLY WITH FOUR LIGHTS CONNECT TO VEHICLE HARNESS CONNECT TO JUMPER HARNESS...

Страница 37: ...son Ave Santa Fe Springs CA 90670 800 227 4116 FAX 888 771 7713 37 ELECTRICAL SCHEMATIC HOUSING COVER ASSEMBLY FOREIGN VEHICLE WITH 6 LIGHTS SYSTEM DIAGRAMS CONNECT TO JUMPER HARNESS CONNECT TO VEHICL...

Страница 38: ...RING VALVE Coil Resistance 6 6 70 F 15 26 7 70 F 15 Ampere 1 8A 0 9A Coil terminal torque 15 45 lb in max Valve cartridge torque 25 30 lb ft max Coil nut torque 15 45 lb in FOLD UNFOLD VALVE Coil Resi...

Страница 39: ...s table for torquing electrical or hydraulic hose connections on the pump assembly CAUTION GRADE 8 BOLT TIGHTENING TORQUE DIAMETER THREAD PITCH TORQUE 1 4 20 10 14 lb ft 1 4 28 11 16 lb ft 5 16 18 20...

Страница 40: ......

Отзывы: