5.

 Insert straight fi tting (Kit item) in the oil 

fi lter outlet and tighten 

(FIG. 3-1)

. Next, 

thread the NPT end of the 45

º

 elbow in 

the reservoir 

(FIG. 3-1)

. Tighten elbow 

in position horizontal to the fl oor of the 
pump box 

(FIG. 3-1)

.

INSTALLING NEW FITTINGS 

(SINGLE HYDRAULIC PUMP SHOWN)

FIG. 3-1

45º ELBOW

STRAIGHT

FITTING

FILTER

OUTLET

RESERVOIR

PARALLEL

STRAIGHT

FITTING

45º ELBOW

6.

 Connect straight end of new hose 

(Kit item) to 45

º

 elbow 

(FIG. 3-2)

Then, connect the 90

º

 end of the 

hose to the straight fitting on the filter 
outlet

 (FIG. 3-2)

.

NOTE:

 Keep both hose connectors 

loose until the new hose is 
routed and both ends are 
connected. Ensure the hose 
is not twisted, does not 
have sharp turns, and does 
not rub against the reservoir 
or any other parts.

90º 

CONNECTOR

CONNECTING NEW HYDRAULIC HOSE

(SINGLE HYDRAULIC PUMP SHOWN)

FIG. 3-2

STRAIGHT

CONNECTOR

7.

 After hose is connected on 

both ends and routed correctly, 
tighten both hose connectors 
securely 

(FIG. 3-2)

8.

 Remove fi ller cap. Refi ll reservoir 

with oil from step 3. If oil is 
contaminated, change the oil 
according to the instructions in the 

BMRA Maintenance Manual

. New 

oil is not provided with this kit. 

FILTER

FILTER

9.

 Reconnect battery power to the 

hydraulic pumps by turning 

ON 

the 

master disconnect switch at the pump 
box. Refer to 

BMRA Operation 

Manual

 for detailed instructions.