background image

© MAXON Lift Corp. 2016

LIFT CORPORATION 

Sht. 2 of 3 DSG# 

M-16-06

  Rev. 

-

 Date: 02/22/16

2.

 Place clean and empty 5 gallon bucket 

under drain plug of reservoir 

(FIG. 2-1)

.

DRAIN PLUG

CAUTION

Keep dirt, water and other contaminants from entering the hydraulic system. 
Before opening the hydraulic fl uid reservoir fi ller cap, drain plug and hydraulic 
lines, clean up contaminants that can get in the openings. Also, protect the 
openings from accidental contamination. 
Never mix synthetic fl uids with conventional hydraulic fl uids. Hydraulic system 
must be purged if the fl uids are mixed.

NOTE:

 Keep the hydraulic oil 

clean so it can be used 
refi ll the reservoir.

3.

 Remove drain plug 

(FIG. 2-1)

. Drain 

hydraulic fl uid from reservoir. Reinstall 
drain plug and tighten securely.

DRAINING OIL FROM RESERVOIR

(SINGLE HYDRAULIC PUMP SHOWN)

FIG. 2-1

4.

 Disconnect hydraulic line from 90

º

 

elbow on the oil fi lter outlet 

and 

the 90

º

 

elbow on reservoir 

(FIG. 2-2)

. Next, 

remove the 90

º

 elbow from reservoir 

(FIG. 2-2)

. Then, remove the 90

º

 elbow 

from oil fi lter outlet 

(FIG. 2-2)

REMOVING HYDRAULIC LINE & 90º ELBOWS  

(SINGLE HYDRAULIC PUMP SHOWN)

FIG. 2-2

HYDRAULIC 

LINE

90º ELBOW

90º 

ELBOW

FILTER

OUTLET

RESERVOIR

FILTER

FILTER