Specifications
Technical Data
maxon motor control
2-8
Document ID: rel7132
ESCON Servo Controller
Edition: November 2018
ESCON 36/3 EC Hardware Reference
© 2018 maxon motor. Subject to change without prior notice.
Table 2-4
Technical Data
Figure 2-1
Derating Output Current
Table 2-5
Limitations
Environmental
Conditions
Temperature
Operation
−30…+45 °C
Extended range
*1)
+45…+78 °C
Derating
Storage
−40…+85 °C
Altitude
*2)
Operation
0…6’000 m MSL
Extended range
*1)
6’000…10’000 m MSL
Derating
Humidity
5…90% (condensation not permitted)
*1)
Operation within the extended range (temperature and altitude) is permitted. However, a respective derating (declina-
tion of output current I
cont
) as to the stated values will apply.
*2)
Operating altitude in meters above Mean Sea Level, MSL.
ESCON 36/3 EC (414533)
Protection functionality
Switch-off threshold
Recovery threshold
Undervoltage
7.2 V
7.4 V
Overvoltage
43 V
41 V
Overcurrent
13.5 A
—
Thermal overload
95 °C
85 °C