© Copyright 2014. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006 Tel: 973-244-7300 Fax: 973-244-7333 Email: [email protected]
Triple Head:
Rev: 6/20/2014
1. All units must be individually connected to the AC supply (120-277 VAC):
Black = Line
White = Neutral
Green= Ground
2. Line connection to be made to switch lead from source.
Driver Replacements:
Contact your local MaxLite® representative or MaxLite® to receive replacements
for drivers.
Step 1
: Disconnect the power by turning off the
circuit breaker or by removing the appropriate
fuse at the fuse box.
*Turning the power off using the light switch is not
sufficient to prevent electrical shock.
Step 2:
Disconnect the black LED Module
connector to disconnect Module from driver.
Step 3
: Remove four (4) screws and front plate
from connector box to expose wire connections.
Step 4:
Disconnect all wiring connections.
Step 5:
Loosen up nylon liquid tight strain relief
fitting to remove driver cord.
Step 6
: Unscrew two (2) screws to remove
driver cover.
Step 7:
Remove four (4) screws to dismount
driver from driver plate.
Step 8
: Remove screw for strain relief clip
attached to mounting bracket of driver plate.
Step 9
: Replace with new driver.
Step 10
: Reverse steps 9 to 3 to assemble
fixture.
Step 11
: Restore Power.