background image

© Copyright 2021. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006   Tel: 800-555-5629   Fax: 973-244-7333   Email: [email protected]

Page: 2
REV: 10/14/21

Installation & Operation

Drill fixed holes on the pole for direct bracket

Operating Instructions                                                                                                               ARE Series

MaxLite ARE High Efficiency Area Luminaires

®

A: Flexible Arm Mounting:

This fixture can be mounted to a square pole or round pole using the RPA (Round Pole Adapter). The flexible arm can be aimed 
0 to 78° both upward and downward in 30° increments (see 

FIG. 2

).

1.

If there is no existing hole pattern on the pole, drill holes according to the pattern in 

FIG. 3

.

2.

Open the side cover plate on the mounting arm by loosening the 4 M3 screws. (See 

FIG. 4

).

3.

Attach the round pole adapter to the mounting bracket if needed. Use the EVA gasket and thread plate if 
needed as shown in 

FIG. 5

.

Fig. 2

Fig. 3

Fig. 4

Fig. 5

General Wiring Diagram

CAUTION: Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply.

Connecting panels to AC source supply: All units must be individually connected to the AC supply.     
Black = Line, White = Common, Green = Ground

Fig. 1

Содержание 108249

Страница 1: ...sted junction box WARNING RISK OF ELECTRICALSHOCK Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the power when you perform any maintenance...

Страница 2: ...78 both upward and downward in 30 increments see FIG 2 1 If there is no existing hole pattern on the pole drill holes according to the pattern in FIG 3 2 Open the side cover plate on the mounting arm...

Страница 3: ...ntinued 4 Secure Pole mount bracket to the pole with 2 M10 50 internal Hex head bolts See FIG 6 Wire the fixture using UL listed water proof wire connectors Use the wiring diagram as shown See FIG 7 5...

Страница 4: ...pfitter fits on industry standard 2 3 8 OD tenons or brackets Connect the power leads properly make the wiring connections see FIG 9 and lay the wires in the pole 1 Once completed insert the slipfitte...

Страница 5: ...RTH HEREIN IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM LOSS OF USE PROFITS BUSINESS OR GOODWILL LABOR COS...

Страница 6: ...E D branchez l alimentation lectrique au fusible ou au disjoncteur avant de connecter le luminaire la source d alimentation D branchez l alimentation lorsque vous effectuez des travaux d entretien V r...

Страница 7: ...dans la FIG 5 Vis M3 Plaque de couverture Silicone Fig 2 Fig 3 Fig 4 Adaptateur rond pour poteau EVA Adaptateur rond pour poteau EVA Vis M3 Fig 5 Sch ma g n ral de c blage PR CAUTION D branchez l ali...

Страница 8: ...avec les 4 vis M3 voir la FIG 8 6 Pour orienter le luminaire desserrez le boulon central d articulation M16x45 sur le bras orientez de 0 90 en toute direction 7 V rifiez l installation pour confirmer...

Страница 9: ...t fixez le au poteau voir la FIG 11 3 Pour orienter le luminaire desserrez le boulon central d articulation M16x45 sur le bras orientez de 0 90 en toute direction 4 V rifiez l installation pour confir...

Страница 10: ...NE SERA EN AUCUN CAS RESPONSABLE DES DOMMAGES PARTICULIERS ACCESSOIRES OU CONS CUTIFS Y COMPRIS SANS S Y LIMITER LES DOMMAGES R SULTANT DE LA PERTE D UTILISATION DES B N FICES DES AFFAIRES OU DE LA B...

Отзывы: