Operating Instructions                                                                                                               ARE Series

MaxLite ARE High Efficiency Area Luminaires

• This fixture is designed for outdoor lighting service, and should not be 

used in areas of limited ventilation, or in high ambient temperatures.

• Before installing light fixtures, read and understand all  cautions, 

warnings, instructions, and product labels. Failure to do so could 
result in injury and/or void the warranty. 

• Installation should be done by a qualified electrician. Make sure power 

is OFF before installing or maintaining fixture.

• Risk of injury or damage. Unit will fall if not installed properly. 

Follow installation instructions.

• To reduce the risk of death, personal injury or property damage from fire, 

electric shock, falling parts, cuts/abrasions, and other hazards read all 
warnings and instructions included with and on the fixture box and all
fixture labels.

• Before installing, servicing, or performing routine maintenance upon 

this equipment, follow these general precautions.

• Commercial installation, service and maintenance of luminaires 

should be performed by a qualified licensed electrician.

• DO NOT INSTALL DAMAGED PRODUCT!

• This fixture is intended to be connected to a properly installed and grounded UL listed junction box.

WARNING:

RISK OF ELECTRICALSHOCK
• Turn off electrical power at fuse or circuit breaker box before wiring fixture 

to the power supply.

• Turn off the power when you perform any maintenance.
• Verify that supply voltage is correct by comparing it with the luminaire label information.
• Make all electrical and grounded connections in accordance with the National Electrical 

Code and any applicable local code requirements.

• All wiring connections should be capped with UL approved wire connectors. 

CAUTION: 

RISK OF INJURY
• Unit will fall if not installed properly. Follow installation instructions.
• Wear gloves and safety glasses at all times when removing luminaire from carton, installing, 

servicing or performing maintenance.

• Avoid direct eye exposure to the light source while it is on.
• Account for small parts and destroy packing material, as these may be hazardous to children.

CAUTION: 

RISK OF FIRE
• Keep combustible and other materials that can burn away from luminaire and lamp/lens.
• MIN 90°C SUPPLY CONDUCTORS

Models:

ARE Series
Operating characteristics:

Operating temperature: -40°C  to 50°C
Input voltage range: 100-277Vac, 277-480Vac, 50/60Hz

 

   

 

 

 

 

   

  

 

   

  

 

            

 

         

         

 

          

         

1

 

          

   

   

   

   

   

 

   

   

   

   

 

 

         

 

           

         

 

        

         

 

        

   

   

   

   

   

 

   

   

   

               

 

         

   

   

   

   

   

 

   

   

   

               

 

           

   

   

   

   

   

 

 

   

   

   

   

 

               

 

           

   

   

   

   

   

 

   

   

   

 

   

   

   

   

   

 

   

   

   

  

           

 

           

 

  

    

               

 

         

 

  

®

Picture is for illustration purposes only. 
Your model may vary.

General Safety Information

© Copyright 2021. MaxLite, Inc. All Rights Reserved.
12 York Ave, West Caldwell, NJ 07006   Tel: 800-555-5629   Fax: 973-244-7333   Email: [email protected]

Page: 1
REV: 10/14/21

Содержание 108249

Страница 1: ...sted junction box WARNING RISK OF ELECTRICALSHOCK Turn off electrical power at fuse or circuit breaker box before wiring fixture to the power supply Turn off the power when you perform any maintenance...

Страница 2: ...78 both upward and downward in 30 increments see FIG 2 1 If there is no existing hole pattern on the pole drill holes according to the pattern in FIG 3 2 Open the side cover plate on the mounting arm...

Страница 3: ...ntinued 4 Secure Pole mount bracket to the pole with 2 M10 50 internal Hex head bolts See FIG 6 Wire the fixture using UL listed water proof wire connectors Use the wiring diagram as shown See FIG 7 5...

Страница 4: ...pfitter fits on industry standard 2 3 8 OD tenons or brackets Connect the power leads properly make the wiring connections see FIG 9 and lay the wires in the pole 1 Once completed insert the slipfitte...

Страница 5: ...RTH HEREIN IN NO EVENT WILL MAXLITE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION DAMAGES RESULTING FROM LOSS OF USE PROFITS BUSINESS OR GOODWILL LABOR COS...

Страница 6: ...E D branchez l alimentation lectrique au fusible ou au disjoncteur avant de connecter le luminaire la source d alimentation D branchez l alimentation lorsque vous effectuez des travaux d entretien V r...

Страница 7: ...dans la FIG 5 Vis M3 Plaque de couverture Silicone Fig 2 Fig 3 Fig 4 Adaptateur rond pour poteau EVA Adaptateur rond pour poteau EVA Vis M3 Fig 5 Sch ma g n ral de c blage PR CAUTION D branchez l ali...

Страница 8: ...avec les 4 vis M3 voir la FIG 8 6 Pour orienter le luminaire desserrez le boulon central d articulation M16x45 sur le bras orientez de 0 90 en toute direction 7 V rifiez l installation pour confirmer...

Страница 9: ...t fixez le au poteau voir la FIG 11 3 Pour orienter le luminaire desserrez le boulon central d articulation M16x45 sur le bras orientez de 0 90 en toute direction 4 V rifiez l installation pour confir...

Страница 10: ...NE SERA EN AUCUN CAS RESPONSABLE DES DOMMAGES PARTICULIERS ACCESSOIRES OU CONS CUTIFS Y COMPRIS SANS S Y LIMITER LES DOMMAGES R SULTANT DE LA PERTE D UTILISATION DES B N FICES DES AFFAIRES OU DE LA B...

Отзывы: