![maximo PV4048 HM Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/maximo/pv4048-hm/pv4048-hm_user-manual_1744704029.webp)
28
Charging algorithm for
lead acid battery
Charging algorithm for
Lithium battery
Joint “AC in” and Solar Charging
INVERTER MODEL
4048/60A
5048/60A
4048/80A
5048/80A
Max Charging Current
120A
140A
Default Charging Current
60A
80A
Table 4 General Specifications
INVERTER MODEL
4048/60A
5048/60A
4048/80A
5048/80A
Certification
IEC62109-1, IEC62109-2, SAA180814, CE
Operating Environment
IP20 Indoor use only, avoid direct sunlight
Operating Temperature Range
0
℃
to 55
℃
Storage temperature
-15
℃
to 60
℃
Back feed current to array
No back feed
Inrush current
40A
40A
Max output fault current
20.9A
26A
Max output overcurrent protection
15.3A
19.1A
Dimension (D*W*H), mm
354 x 272 x 128
528 x295 x141
Net Weight, kg
12.5
13.5