Maxim 88801 Скачать руководство пользователя страница 3

1. To reduce the risk of electric shock, insure

electricity  has  been  turned  off  at  the

circuit  breaker  or  fuse  box  before

beginning.

2. All wiring must be in accordance with the

National  Electrical  Code  and  local

electrical  codes.  Electrical  installation

should  be  performed  by  a  qualified

licensed electrician.

3.

WARNING:

 To reduce the risk of electrical

shock  and  fire,  do  not  use  this  fan  with

any solid-state fan speed control device.

4.

WARNING:

 To reduce the risk of personal

injury, use only the two steel screws (and

lock  washers)  provided  with  the  outlet

box  for  mounting  to  the  outlet  box.  Most

outlet  boxes  commonly  used  for  the

support  of  lighting  fixtures  are  not

acceptable for fan support and may need

to  be  replaced,  consult  a  qualified

electrician if in doubt.

5. The outlet box and support structure must

be  securely  mounted  and  capable  of

reliably  supporting  a  minimum  of  50

pounds. Use only UL Listed outlet boxes

marked 

"FOR FAN SUPPORT"

.

6. The fan must be mounted with a minimum

of 7 feet clearance from the trailing edge

of the blades to the floor.

7. Do not operate reversing switch while fan

blades  are  in  motion.   Fan  must  be

turned  off  and  blades  stopped  before

reversing blade direction.

8. Avoid  placing  objects  in  the  path  of  the

blades.

9. To avoid personal injury or damage to the

fan  and  other  items,  be  cautious  when

working around or cleaning the fan.

10. Do  not  use  water  or  detergents  when

cleaning  the  fan  or  fan  blades.   A  dry

dust  cloth  or  lightly  dampened  cloth  will

be suitable for most cleaning.

11. After  marking  electrical  connections,

spliced  conductors  should  be  turned

upward  and  pushed  carefully  up  into

outlet  box.  The  wires  should  be  spread

apart  with  the  grounded  conductor  and

the  equipment-grounding  conductor  on

one side of the outlet box.

12. Electrical  diagrams  are  reference  only.

Light kit that are not packed with the fan

must  be  UL  Listed  and  marked  suitable

for  use  with  the  model  fan  you  are

installing.  Switches  must  be  UL  General

Use  Switches.  Refer  to  the  Instructions

packaged with the light kits and switches

for proper assembly.

2

2. SAFETY RULES

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK OR PERSONAL INJURY, MOUNT 

FAN TO OUTLET BOX MARKED 

"ACCEPTABLE FOR FAN SUPPORT".

WARNING

TO REDUCE THE RISK OF PERSONAL 

INJURY, DO NOT BEND THE BLADE 

BRACKETS (ALSO REFERRED TO AS 

FLANGES) DURING ASSEMBLY OR AFTER 

INSTALLATION. DO NOT INSERT OBJECTS IN 

THE PATH OF THE BLADES.

Содержание 88801

Страница 1: ...PRODUCT NAME Cupola 3 Blade Fan w LED FKT ITEM NUMBER 88801 Please consult your electrician for hanging fixture and wiring MADE IN CHINA ...

Страница 2: ...screws 10 fiber washers 10 Couping cover Couping Ring Wall control receiver 4 Balance Kit Blade set 3 L M H 0 h I I h ...

Страница 3: ...ades are in motion Fan must be turned off and blades stopped before reversing blade direction 8 Avoid placing objects in the path of the blades 9 To avoid personal injury or damage to the fan and other items be cautious when working around or cleaning the fan 10 Do not use water or detergents when cleaning the fan or fan blades A dry dust cloth or lightly dampened cloth will be suitable for most c...

Страница 4: ...he moving weight of the fan at least 50 lbs Do not use plastic outlet boxes Fig To hang your fan where there is an existing fixture but no ceiling joist you may need an installation hanger bar as shown in Figure 4 1 2 and 3 are examples of different ways to mount the outlet box Note You may need a longer downrod to maintain proper blade clearance when installing on a steep sloped ceiling Fig 3 Out...

Страница 5: ...the fan and align th Step 1 Turn the light kit clockwise to loosen the light kit Fig 5 e blade screw hole with the screw hole of the center band Fig 6 Lock the blades with screws and washer Step 3 Step 4 The lamp panel is connected to the wire Fig 7 Turn the light kit counterclockwise to lock the light kit Fig 7 Step 5 Light kit Light kit ...

Страница 6: ... center hole in the ceiling hanger bracket Step 4 Screws removed at canopy lock the bell and hanger Step 5 Remove the hanger pin lock pin and set screws from the top of the motor assembly Step 6 Route wires exiting from the top of the fan motor through the canopy and then through the ball down rod Fig 9 Step 7 Align the holes at the bottom of the down rod with the holes in the collar on top of the...

Страница 7: ...tral household wire Step 3 Connect the fan ground wire green to the household ground wire Step 4 After connecting the wires spread them apart so that the green and white wires are on one side of the outlet box and the black and the blue wires are on the other side Turn the connecting nuts upward and push the wiring into the outlet box WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR OTHER PERS...

Страница 8: ...h box and secure it with the two screws at each end of the unit this procedure is the same as if you were to put the original wall switch back into the wall Now attach the face plate to the Wall Control Fig 13 Connect BLACK wire from A C power supply to BLACK wire AC IN L from the wall mounted control Connect BLACK wire from the ceiling fan to BLACK wire TO MOTORL L from the wall mounted control C...

Страница 9: ... reverse switch to turn the forward and reverse switch As shown in fig 16 turn the forward and reversal switch counterclockwise to turn the fan for reverse winter and turn the forward and reverse switch clockwise to turn the fan for Forward rotation summer 8 USE OFFORWARD AND REVERSE SWITCH screwdriver SUMMER WINTER Fig 16 W I N T E R SUM M ER ...

Страница 10: ...Joint cover Safety Pin Washer and Retainer Clip Terminal 9 Fig 17 9 Couping Ring Turn the light kit clockwise to tighten it Turn the light kit counterclockwise to loosen it ...

Страница 11: ... switch controls directions forward switch down or reverse switch up NOTE Wait for fan to stop before changing the setting of the slide switch Warm weather Forward A downward airflow creates a cooling effect as shown in Fig 18 This allows you to set your air conditioner on a warmer setting without affecting your comfort Cool weather Reverse An upward airflow moves warm air off the ceiling area as s...

Страница 12: ...12 TROUBLESHOOTING 11 CARE OF YOUR FAN 11 ...