15. Set  up  the terminal program to run on the PC using the following steps. Before 

loading the executable firmware file  on the FPGA, the terminal program on the 
PC should be running. The example firmware running on the FPGA 
communicates with the PC via a USB port set up to emulate a serial port (UART). 
To establish this communication link, the PC must be configured with the 
appropriate Windows drivers. A suitable terminal program such as Tera Term or 
HyperTerminal should be invoked. 
 
The micro USB (J3) on the LX9 is the communication port. The LX9 utilizes the 
Silicon Labs CP2102 USB-UART  bridge IC, so you need to install  Silicon Labs’ 
virtual COM port (VCP) driver for their CP210x device family.  These may be 
obtained from the Silicon Labs website (www.silabs.com). 
 
Once installed, Windows will assign a previously unused COM port. Use the 
Windows 

Control Panel | System | Device Manager

 to determine the COM port 

number. (It will be named 

Silicon Labs CP210x USB to UART Bridge

.) Make a 

note of which COM port this is. That information is needed in the next step. 
 
Next, a terminal emulation program needs to be installed and launched. For 
Windows XP® and earlier systems, the HyperTerminal  program is the usual 
choice. However, since HyperTerminal  was eliminated from Windows 7, it may 
be necessary to locate an alternative. Several are available; one good choice is 
called Tera Term  (http://ttssh2.sourceforge.jp/).  Whatever  terminal  program you 
choose, the communication should be set up by opening the COM port number 
previously described above and the port configured as:  
 
bits per second: 

115,200

;    

 
data bits: 

8

;  

 
parity: 

none

;  

 
stop bits: 

1

 
flow control: 

none

 
 
 
 
 
 
 
 
 
 

Содержание Alameda MAXREFDES24#

Страница 1: ...lied Maxim Integrated reserves the right to change the circuitry and specifications without notice at any time Maxim Integrated 160 Rio Robles San Jose CA 95134 USA 1 408 601 1000 2014 Maxim Integrate...

Страница 2: ...oBoard Quick Start Guide 2 Table of Contents 1 Required Equipment 3 2 Overview 3 3 Included Files 5 4 Procedure 6 5 Code Documentation 18 6 Appendix A Project Structure and Key Filenames 19 7 Trademar...

Страница 3: ...ing pages The Alameda MAXREFDES24 subsystem reference design will be referred to as Alameda throughout this document 1 Connect the Alameda board to the J4 and J5 ports of an LX9 MicroBoard as shown in...

Страница 4: ...Alameda MAXREFDES24 LX9 MicroBoard Quick Start Guide 4 Figure 1 Alameda Board Connected to LX9 Kit Figure 2 Pmod Connector Alignment...

Страница 5: ...e MicroBlaze core the support hardware required to run the MicroBlaze and the peripherals that interface to the Pmod ports Software is supplied as a Xilinx software development kit SDK project that in...

Страница 6: ...s used to communicate with a PC through a terminal program See step 16 for USB driver installation 7 Connect the J6 JTAG connector of the LX9 MicroBoard to a PC through a Xilinx programming cable This...

Страница 7: ...11 SDK will prompt for a workspace directory which is the location where the software project is located For this example it is C designs maxim RD24V01_00 RD24_LX9_V01_00 Design_Files sdkWorkspace Cli...

Страница 8: ...LX9 MicroBoard Quick Start Guide 8 12 Review the SDK IDE The Project Explorer in the upper left tab should have three components as shown in the image below If all three subfolders are present you can...

Страница 9: ...h the File Import menu expand the General folder and select Existing Projects into Workspace Click Next Set the root directory to C designs maxim RD24V01_00 RD24_LX9_V01_00 Design_Files sdkWorkspace a...

Страница 10: ...cted as well as an FPGA BMM bmm file Be sure to select the bit file and the bmm file by using the paths below Bitstream C designs maxim RD24V01_00 RD24_LX9_V01_00 Design_Files top bit BMM File C desig...

Страница 11: ...family These may be obtained from the Silicon Labs website www silabs com Once installed Windows will assign a previously unused COM port Use the Windows Control Panel System Device Manager to determ...

Страница 12: ...12 16 Use the Xilinx SDK to download and run the executable ELF ELF file on the MicroBlaze using the following steps Right click the mouse while the MAXREFDES24 C project is selected choose the Run As...

Страница 13: ...Alameda MAXREFDES24 LX9 MicroBoard Quick Start Guide 13 Next double click the mouse on the Xilinx C C ELF menu...

Страница 14: ...Alameda MAXREFDES24 LX9 MicroBoard Quick Start Guide 14 Next press the Search Project button...

Страница 15: ...Alameda MAXREFDES24 LX9 MicroBoard Quick Start Guide 15 Double click on the MAXREFDES24 elf binary...

Страница 16: ...Quick Start Guide 16 Verify the application is selected on the Main tab and press the Run button Once the Debug MAXREFDES24 configuration is set up once you just need to press the Run button if you e...

Страница 17: ...Guide 17 At this point the application will be running on the MicroBlaze and the terminal program should show the menu below Make the desired selections by pressing the appropriate keys on the keyboar...

Страница 18: ...e documentation can be found at C RD24V01_00 RD24_LX9_V01_00 Code_Documentation To view the code documentation in HTML format with a browser open the MainPage html file To view the code documentation...

Страница 19: ...rademark of Xilinx Inc MicroBlaze is a trademark of Xilinx Inc Pmod is a trademark of Digilent Inc Spartan 6 is a registered trademark of Xilinx Inc WebPACK is a trademark of Xilinx Inc Windows is a r...

Страница 20: ...Alameda MAXREFDES24 LX9 MicroBoard Quick Start Guide 20 8 Revision History REVISION NUMBER REVISION DATE DESCRIPTION PAGES CHANGED 0 3 14 Initial release...

Страница 21: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Maxim Integrated MAXREFDES24...

Отзывы: