![Maxcess MAGPOWR DLCA NET-IP65-ECAT Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/maxcess/magpowr-dlca-net-ip65-ecat/magpowr-dlca-net-ip65-ecat_user-manual_1743219042.webp)
SPECIFICATIONS
www.maxcessintl.com
DLCA NET-IP65-ECAT
MI 850A366 1
Page 42 of 44
9.0
Specifications
Supply voltage range - 24 VDC ±10%
Proper earth grounding is required.
Note that the negative supply and earth ground
are interconnected on the product.
The power supply must have an SELV output,
such as Puls ML15.241, Mean Well MDR-20-24
or equivalent.
The Mean Well MDR-20-24 can be purchased
from Fife as part number 93157-024.
Supply current - 175 mA, maximum
Internal fuse - 6.3 A, fast blow.
Maximum gain - 32:1
Tare adjustment - 90% of load cell rating.
Load cell excitation voltage – 5 or 7.5 VDC, 200 mA maximum
Load cell input – 1.5 mV/V to 100 mV/V
Tension update rate - 2 ms
Tension resolution - 14-Bit
Ethernet - 2 ports
10/100 Mbps
Fieldbus support - EtherCAT
®
EtherCAT is registered trademark and patented
technology, licensed by Beckhoff Automation
GmbH, Germany.
Temperature effect on zero - 0.01% of full scale per °C
Temperature range
Operating
Storage
-
-
0° to 60°C (32° to 140°F)
-20° to 80°C (-4° to 176°F)
Enclosure - IP65