Messages and Error Messages

0xFFFF  Acknowledge
0xF000   Parameter is Read Only
0xF001   Invalid parameter ID
0xF002   Invalid Read/Write control value
0xF003  

Data is below the minimum value for this parameter

0xF004  

Data is above the maximum value for this parameter

0xF005  

Parameter is being edited by the User from the Cygnus front panel

     Reasons for Parameter is not changeable
  0xD001   Security Code is set.
  0xD002   System is Not Running
  0xD003   System is Not Stopped
  0xD004   System Type is not Rewind
 

0xD005   Security Code is set, or, System is Not Stopped, or, System is Not in Manual

  0xD006   Security 

is 

LOCKED

  0xD007   Security 

is 

UNLOCKED

 

0xD008   Security code did not verify, security is UNLOCKED

  0xD009   Value is not in range
 

0xD00A   Sensor Type is set to NONE

 

0xD00B   Diameter sensor is set to NONE

 

0xD00C 

Security Code is set, or, System in Not in Manual

 

0xD00D 

Security is LOCKED, or, System is Not Running

 

0xD00E   The same analog input can not be configured for multiple functions

 

0xD00F   Undefined,  

Load Cell calibration is complete

 

0xD010   Undefined,  Auto Tune will be complete after a control is designed

  0xD011   System is Not in Manual
 

0xD012   System is Not Running and In Auto Mode

  0xD013   Tension On/Off is Not Toggle
 

0xD014   System is Not Stopped, or, Security is LOCKED

  0xD015   Undefined,  

Compensation is Optimal

 

0xD016   Undefined,  The Oscillation may be an instability or an outside disturbance

  0xD017   Undefined,  

Stability is Optimal

  0xD018   Undefined,  

Calibrate Inertia/Accel complete

  0xD019   Diameter Not received from Fieldbus
 

0xD01A   System must be UNLOCKED, and, Running in Auto Mode, and, with Tension On

 

0xD01B   Undefined,  Not Stable?  Switch to Quick Stabilize

 

0xD01C 

Undefined,  Gain Scheduling and Out-Of-Round compensation have been turned Off

 

0xD01D 

System is Not in Hold, or, Tension is On.

  0xD01E   Gain Scheduling is active.
 

0xD01F   Undefined, Remember to switch to Auto mode.

 

0xD020   Setpoint is configured for Remote analog input.

 

0xD021   Setup Number is configured for Remote analog input.

 

0xD022   Can not change while diameter type is Velocity/RPM

 

0xD023   Can not change Remote setup number while System is Not Stopped.

Содержание Magpowr COMMKIT-DN

Страница 1: ...P PDF file AnyBus S Ethernet IP IT The EDS and GSD configuration files are also available on the same web page DeviceNet EDS file AnyBus S DeviceNet Parallel Profibus DP GSD file AnyBus S Profibus DP...

Страница 2: ...ch has the same message_ID The parameter_ID of the response is the same if there were no errors otherwise the parameter_ID contains the error number The read write_control of the response is set to WR...

Страница 3: ...fined data integer undefined data float undefined Cygnus Error response message_ID 2 parameter_ID Error_message_number read write_control 1 data unsigned short undefined data integer undefined data fl...

Страница 4: ...State INT Read Write 0 Off 1 On 9 InertiaCompState INT Read Write 0 Off 1 On 10 NewRollFeature INT Read Write 0 No 1 Yes 11 SpliceFeature INT Read Write 0 No 1 Yes 12 SystemType INT Read Write 0 Unwin...

Страница 5: ...Multiplier FLOAT Read Write 52 StopTime FLOAT Read Write 53 TaperCoreDiameter FLOAT Read Write 54 TaperFullRollDiameter FLOAT Read Write 55 TaperPercentage FLOAT Read Write 56 TensionAlarmDelay FLOAT...

Страница 6: ...erEstimatedLargeSetpoint FLOAT Read Write 103 CalibrationDiameterVoltageSingleMeasured FLOAT Read Write 104 CalibrationDiameterVoltageSingleSetpoint FLOAT Read Write 105 CalibrationDiameterVoltageSmal...

Страница 7: ...WrapAngle FLOAT Read Write 513 Calibration_PWM_Current_Pt1 FLOAT Read Write 514 Calibration_PWM_Current_Pt2 FLOAT Read Write 515 Calibration_PWM_10V_Pt1 FLOAT Read Write 516 Calibration_PWM_10V_Pt2 F...

Страница 8: ...hen this input goes from a 0 to a 1 551 FieldbusRunStopInput UNSIGNED_SHORT Read Write 0 Stop 1 Run 552 FieldbusSpliceInput UNSIGNED_SHORT Read Write 0 Not Splice 1 Splice 553 TensionOffState UNSIGNED...

Страница 9: ...or multiple functions 0xD00F Undefined Load Cell calibration is complete 0xD010 Undefined Auto Tune will be complete after a control is designed 0xD011 System is Not in Manual 0xD012 System is Not Run...

Страница 10: ...onnect the Cygnus to a 10 100Mbit Ethernet network using a CAT5 cable 5 Open a DOS command prompt on a PC running Windows NT 2000 XP 6 In the DOS window type arp s IP address MAC address a Substitute...

Отзывы: