Parameters 500 through 999 are allocated for Non-Setup Selectable Parameters

   Number      Description                                                                   Type                           Read/Write

500

RunStopInputLocation

UNSIGNED_SHORT   Read Only

0=Local Hardware, 1=Fieldbus

501

SpliceJogInputLocation

UNSIGNED_SHORT   Read Only

0=Local Hardware, 1=Fieldbus

502

TensionOnOffMode

UNSIGNED_SHORT   Read Only

0=Toggle Mode, 1=Level Mode

503

DigitalInputVoltageRange

UNSIGNED_SHORT   Read Only

0=5 volt, 1=24 volt

504

DigitalInputActiveState

UNSIGNED_SHORT   Read Only

0=Active Low, 1=Active High

505

RelayCurrentRange

UNSIGNED_SHORT   Read Only

0=5 milliamp, 1=100 milliamp

506

LoadCellType

UNSIGNED_SHORT   Read Only

0=Magpowr, 21 millivolt, 1=500 millivolt, 2=5 volt

507

IsolatedOutputMode

UNSIGNED_SHORT   Read Only

0=4-20 milliamp, 1=10 volt, 2=+/-10 volt

508

IsolatedOutputFunction

UNSIGNED_SHORT   Read Only

0=Torque, 1=Inverse Diameter

509

NonIsolatedOutputFunction

UNSIGNED_SHORT

Read Only

0=Torque, 1=Inverse Diameter

510

FieldbusType

UNSIGNED_SHORT   Read Only

0=None, 1=HMS

511  SensorRating

FLOAT

Read/Write

512  WrapAngle

FLOAT

Read/Write

513  Calibration_PWM_Current_Pt1

FLOAT

Read/Write

514  Calibration_PWM_Current_Pt2

FLOAT

Read/Write

515  Calibration_PWM_10V_Pt1

FLOAT

Read/Write

516  Calibration_PWM_10V_Pt2

FLOAT

Read/Write

517  Calibration_PWM_PM10V_Pt1

FLOAT

Read/Write

518  Calibration_PWM_PM10V_Pt2

FLOAT

Read/Write

519  Calibration_NonIsolatedOutputGain

FLOAT

Read/Write

520  Calibration_TensionOutputGain

FLOAT

Read/Write

521  Calibration_RPM_Actual

FLOAT

Read Only

522  Calibration_Velocity_Actual

FLOAT

Read Only

 

Use for reading of ActualVelocity use FieldbusVelocityIn to set Velocity from

    fieldbus

523  Calibration_RPM_Edit_Setpoint

FLOAT

Read/Write

524  Calibration_Velocity_Edit_Setpoint

FLOAT

Read/Write

525  Calibration_RPM_Pulse_PerRevolution

FLOAT

Read/Write

526   Not Used

----

----

527   Not Used

----

----

528  Calibration_RPM_Pulse_Current

FLOAT

Read/Write

529  Calibration_RPM_Voltage_Gain

FLOAT

Read/Write

530  Calibration_RPM_Voltage_Pt

FLOAT

Read/Write

531  Calibration_RPM_Voltage_Setpoint

FLOAT

Read/Write

532  Calibration_RPM_Voltage_Current

FLOAT

Read/Write

533  Calibration_Velocity_Pulse_Gain

FLOAT

Read/Write

534  Calibration_Velocity_Pulse_Pt

FLOAT

Read/Write

535  Calibration_Velocity_Pulse_Setpoint

FLOAT

Read/Write

Содержание Magpowr COMMKIT-DN

Страница 1: ...P PDF file AnyBus S Ethernet IP IT The EDS and GSD configuration files are also available on the same web page DeviceNet EDS file AnyBus S DeviceNet Parallel Profibus DP GSD file AnyBus S Profibus DP...

Страница 2: ...ch has the same message_ID The parameter_ID of the response is the same if there were no errors otherwise the parameter_ID contains the error number The read write_control of the response is set to WR...

Страница 3: ...fined data integer undefined data float undefined Cygnus Error response message_ID 2 parameter_ID Error_message_number read write_control 1 data unsigned short undefined data integer undefined data fl...

Страница 4: ...State INT Read Write 0 Off 1 On 9 InertiaCompState INT Read Write 0 Off 1 On 10 NewRollFeature INT Read Write 0 No 1 Yes 11 SpliceFeature INT Read Write 0 No 1 Yes 12 SystemType INT Read Write 0 Unwin...

Страница 5: ...Multiplier FLOAT Read Write 52 StopTime FLOAT Read Write 53 TaperCoreDiameter FLOAT Read Write 54 TaperFullRollDiameter FLOAT Read Write 55 TaperPercentage FLOAT Read Write 56 TensionAlarmDelay FLOAT...

Страница 6: ...erEstimatedLargeSetpoint FLOAT Read Write 103 CalibrationDiameterVoltageSingleMeasured FLOAT Read Write 104 CalibrationDiameterVoltageSingleSetpoint FLOAT Read Write 105 CalibrationDiameterVoltageSmal...

Страница 7: ...WrapAngle FLOAT Read Write 513 Calibration_PWM_Current_Pt1 FLOAT Read Write 514 Calibration_PWM_Current_Pt2 FLOAT Read Write 515 Calibration_PWM_10V_Pt1 FLOAT Read Write 516 Calibration_PWM_10V_Pt2 F...

Страница 8: ...hen this input goes from a 0 to a 1 551 FieldbusRunStopInput UNSIGNED_SHORT Read Write 0 Stop 1 Run 552 FieldbusSpliceInput UNSIGNED_SHORT Read Write 0 Not Splice 1 Splice 553 TensionOffState UNSIGNED...

Страница 9: ...or multiple functions 0xD00F Undefined Load Cell calibration is complete 0xD010 Undefined Auto Tune will be complete after a control is designed 0xD011 System is Not in Manual 0xD012 System is Not Run...

Страница 10: ...onnect the Cygnus to a 10 100Mbit Ethernet network using a CAT5 cable 5 Open a DOS command prompt on a PC running Windows NT 2000 XP 6 In the DOS window type arp s IP address MAC address a Substitute...

Отзывы: