Number      Description                                                                   Type                           Read/Write

2

UserConfigLengthUnits

INT

Read/Write

0=inches, 1=feet, 2=millimeters, 3=centimeters, 4=meters

3

UserConfigVelocityUnits

INT

Read/Write

0=inches per minute, 1=feet per minute, 2=millimeters per minute,

3=centimeters per minute, 4=meters per minute

4

UserConfigTimeUnits

INT

Read/Write

0=seconds, 1=minutes, 2=hours

5

UserConfigInertiaUnits

INT

Read/Write

0=pounds*feet^2, 1=kilograms*meter^2

6

AutoManualState

INT

Read/Write

0=Automatic, 1=Manual

7

HoldLevelChangesWith

INT

Read/Write

0=None, 1=Output, 2=Tension, 3=Diameter, 4=Diameter and Tension

8

InertiaAccelState

INT

Read/Write

0=Off, 1=On

9

InertiaCompState

INT

Read/Write

0=Off, 1=On

10

NewRollFeature

INT

Read/Write

0=No, 1=Yes

11

SpliceFeature

INT

Read/Write

0=No, 1=Yes

12

SystemType

INT

Read/Write

0=Unwind, 1=Rewind, 2=Type 1, 3=Type 2, 4=Type 3, 5=Type 4

13

TaperOnOffState

INT

Read/Write

0=Off, 1=On

14

TensionAlarmState

INT

Read/Write

0=Off, 1=On

15

AutoTuneControlType

INT

Read/Write

0=PI, 1=PID, 2=I only

16

DA_SensorPositiveBias

INT

Read/Write

17

DA_SensorNegativeBias

INT

Read/Write

18

DA_ADC_Reference

INT

Read/Write

19

Not Used

---

----

20

GainSchedulingFlag

INT

Read/Write

0=Off, 1=On

21

CalibrationTensionBin

INT

Read/Write

22

OutOfRoundCompFlag

INT

Read/Write

0=Off, 1=On

23

Not Used

---

----

24

SensorOffset

INT

Read/Write

25

Not Used

---

----

26

DiameterCalibrationType

INT

Read/Write

0=Single Point, 1=Two Point

Содержание Magpowr COMMKIT-DN

Страница 1: ...P PDF file AnyBus S Ethernet IP IT The EDS and GSD configuration files are also available on the same web page DeviceNet EDS file AnyBus S DeviceNet Parallel Profibus DP GSD file AnyBus S Profibus DP...

Страница 2: ...ch has the same message_ID The parameter_ID of the response is the same if there were no errors otherwise the parameter_ID contains the error number The read write_control of the response is set to WR...

Страница 3: ...fined data integer undefined data float undefined Cygnus Error response message_ID 2 parameter_ID Error_message_number read write_control 1 data unsigned short undefined data integer undefined data fl...

Страница 4: ...State INT Read Write 0 Off 1 On 9 InertiaCompState INT Read Write 0 Off 1 On 10 NewRollFeature INT Read Write 0 No 1 Yes 11 SpliceFeature INT Read Write 0 No 1 Yes 12 SystemType INT Read Write 0 Unwin...

Страница 5: ...Multiplier FLOAT Read Write 52 StopTime FLOAT Read Write 53 TaperCoreDiameter FLOAT Read Write 54 TaperFullRollDiameter FLOAT Read Write 55 TaperPercentage FLOAT Read Write 56 TensionAlarmDelay FLOAT...

Страница 6: ...erEstimatedLargeSetpoint FLOAT Read Write 103 CalibrationDiameterVoltageSingleMeasured FLOAT Read Write 104 CalibrationDiameterVoltageSingleSetpoint FLOAT Read Write 105 CalibrationDiameterVoltageSmal...

Страница 7: ...WrapAngle FLOAT Read Write 513 Calibration_PWM_Current_Pt1 FLOAT Read Write 514 Calibration_PWM_Current_Pt2 FLOAT Read Write 515 Calibration_PWM_10V_Pt1 FLOAT Read Write 516 Calibration_PWM_10V_Pt2 F...

Страница 8: ...hen this input goes from a 0 to a 1 551 FieldbusRunStopInput UNSIGNED_SHORT Read Write 0 Stop 1 Run 552 FieldbusSpliceInput UNSIGNED_SHORT Read Write 0 Not Splice 1 Splice 553 TensionOffState UNSIGNED...

Страница 9: ...or multiple functions 0xD00F Undefined Load Cell calibration is complete 0xD010 Undefined Auto Tune will be complete after a control is designed 0xD011 System is Not in Manual 0xD012 System is Not Run...

Страница 10: ...onnect the Cygnus to a 10 100Mbit Ethernet network using a CAT5 cable 5 Open a DOS command prompt on a PC running Windows NT 2000 XP 6 In the DOS window type arp s IP address MAC address a Substitute...

Отзывы: