INSTRUCTION MANUAL

COMMKIT-DN, COMMKIT-PB, and COMMKIT-EN Fieldbus Interface Cards

All of the information herein is the exclusive proprietary property of Maxcess International, and is disclosed with the

understanding that it will be retained in confidence and will neither be duplicated nor copied in whole or in part nor

be used for any purpose other than for which disclosed.

Acrobat Reader

®

 is a trademark of

Adobe Systems Incorporated

Copyright 2004, all rights reserved.

Periodically there will be updates to this manual.  The latest version is available at www.magpowr.com or by calling
1-800-MAGPOWR

Introduction

The Cygnus

®

 communicates over either DeviceNet, Profibus-DP, or Ethernet/IP using an HMS AnyBus-S Slave

interface card.  For DeviceNet, Polled I/O data is used.  For Profibus-DP, Cyclic I/O data is used.  For Ethernet IP,
data may be accessed using the GetAttributeSingle service.

Setup

Install the fieldbus specific HMS interface card into the Cygnus (see Cygnus Instruction Manual 850A295 for
installation instructions).  The switch settings for each fieldbus card are described in Chapter 3 of the fieldbus
appendix for the specific interface card, or are available from the HMS website:
http://www.anybus.com/downloads/absdownloads.shtml

 

Anybus-S Slave Individual Fieldbus Appendix

DeviceNet PDF file: AnyBus-S DeviceNet

  

Profibus 

PDF 

file:  AnyBus-S 

Profibus-DP

  

Ethernet/IP 

PDF 

file:  AnyBus-S 

Ethernet/IP+IT

The EDS and GSD configuration files are also available on the same web page.
  

DeviceNet EDS file: AnyBus-S DeviceNet Parallel

  

Profibus-DP 

GSD 

file:  AnyBus-S 

Profibus-DP

Fieldbus Communications

The input/output data area size is 16 bytes.  The data area consists of 4 fields, the message identifier field, the
parameter identifier field, the read/write control field, and the parameter data field.  The message identifier is a
unique number used to distinguish a new message.  Each time the fieldbus sends a new message it must generate
and send a different message identifier.  The parameter identifier is the parameter number of the data the fieldbus
is reading from or writing to the Cygnus.  The read/write control tells whether this message is “a read from the
Cygnus” or “a write to the Cygnus.”  The parameter data field contains the data read or written message.  The
parameter data field consists of three variables one for each data type, unsigned short, integer, and float data.  The
data type area used is determined by the specific parameter selected.

Notes

  All data, both read and written, must be presented in the current Cygnus Unit system.  To enter data using a

different unit system, the unit system must be changed prior to changing or reading the data.

  All setup selectable data, both read and written, must be related to the current Cygnus setup number.  To

change parameters in another setup, the system must be changed to the desired setup number prior to
changing or reading the data.

  The Cygnus considers the entire message to be valid when it detects that the message_ID has changed.
  Numbers are hexadecimal if they start with 0x, and decimal if not.

850A299-1
03/09   Rev. E

Содержание Magpowr COMMKIT-DN

Страница 1: ...P PDF file AnyBus S Ethernet IP IT The EDS and GSD configuration files are also available on the same web page DeviceNet EDS file AnyBus S DeviceNet Parallel Profibus DP GSD file AnyBus S Profibus DP...

Страница 2: ...ch has the same message_ID The parameter_ID of the response is the same if there were no errors otherwise the parameter_ID contains the error number The read write_control of the response is set to WR...

Страница 3: ...fined data integer undefined data float undefined Cygnus Error response message_ID 2 parameter_ID Error_message_number read write_control 1 data unsigned short undefined data integer undefined data fl...

Страница 4: ...State INT Read Write 0 Off 1 On 9 InertiaCompState INT Read Write 0 Off 1 On 10 NewRollFeature INT Read Write 0 No 1 Yes 11 SpliceFeature INT Read Write 0 No 1 Yes 12 SystemType INT Read Write 0 Unwin...

Страница 5: ...Multiplier FLOAT Read Write 52 StopTime FLOAT Read Write 53 TaperCoreDiameter FLOAT Read Write 54 TaperFullRollDiameter FLOAT Read Write 55 TaperPercentage FLOAT Read Write 56 TensionAlarmDelay FLOAT...

Страница 6: ...erEstimatedLargeSetpoint FLOAT Read Write 103 CalibrationDiameterVoltageSingleMeasured FLOAT Read Write 104 CalibrationDiameterVoltageSingleSetpoint FLOAT Read Write 105 CalibrationDiameterVoltageSmal...

Страница 7: ...WrapAngle FLOAT Read Write 513 Calibration_PWM_Current_Pt1 FLOAT Read Write 514 Calibration_PWM_Current_Pt2 FLOAT Read Write 515 Calibration_PWM_10V_Pt1 FLOAT Read Write 516 Calibration_PWM_10V_Pt2 F...

Страница 8: ...hen this input goes from a 0 to a 1 551 FieldbusRunStopInput UNSIGNED_SHORT Read Write 0 Stop 1 Run 552 FieldbusSpliceInput UNSIGNED_SHORT Read Write 0 Not Splice 1 Splice 553 TensionOffState UNSIGNED...

Страница 9: ...or multiple functions 0xD00F Undefined Load Cell calibration is complete 0xD010 Undefined Auto Tune will be complete after a control is designed 0xD011 System is Not in Manual 0xD012 System is Not Run...

Страница 10: ...onnect the Cygnus to a 10 100Mbit Ethernet network using a CAT5 cable 5 Open a DOS command prompt on a PC running Windows NT 2000 XP 6 In the DOS window type arp s IP address MAC address a Substitute...

Отзывы: