INSTALLATION
3 - 6
DSE-15
www.maxcess.eu
MI 1094 1
The reflector of the sensor must be inclined at an angle of
+(3°±2°) or -(3°±2°). This will prevent undesirable reflected
light from striking the sensor
If the material is recorded with a glossy or matte surface, the red
light beam should strike the web level at a certain angle.
table and
A minimum distance must be maintained for reflectors with a
rough structure.
table and
Alignment of reflector and
sensor
To prevent an undesirable change in the web position and guide
point when the web plane changes, the sensor must be mounted
at an angle of 90° to the web surface.
Note:
If a positioner is used to move the sensor, the red light beam
must strike the reflector along the entire path the sensor moves
without faults.
Material
W
reflective
5° - 45°
matte
0° - 45°
Material
X Y
opaque
up to 1000mm
10 - 90% of X
transparent
150 - 1000mm
max.
¾
X