INSTALLATION
3 - 7
DSE-15
www.maxcess.eu
MI 1094 1
In
stal
la
tion
.fm
1 Reflector
2 Material web
3 Web edge
HS Plane change
RPV Guide point change with a tilted sensor due to a
plane change of the web
Figure 3.6: Undesirable guide point change with plane change due to faulty assembly
90
°
90
°
H
S
RPV
2
3
1
Correct assembly
Faulty assembly