INSTALLATION
3 - 5
DSE-15
www.maxcess.eu
MI 1094 1
In
stal
la
tion
.fm
Distance between reflector
and sensor
The web is located between the sensor and reflector.
ATTENTION
The sensor could become unusable.
Depending on the material of the controlled web, it is possible a
grinding of the material web or a plane change could strike and
damage the sensor or reflector.
Make certain there is sufficient distance between the web
and sensor.
1 Sensor
2 Red light beam
3 Reflector
4 Material web
5 Web guide direction
Figure 3.5: Application of reflected light sensor DSE-15
3
°
2
°
-3
°
2
°
W
Y
X
3
4
2
5
1