www.maxcess.com
FIFE-500 MAX Narrow Web Guide
MI 2700XXXXX 18
CHAPTER 4
ASC
41 / 77
4.5 ASC
Automatic Sensor Control (ASC) can be used under certain
conditions where it is desirable to ignore sudden sensor input changes. A
typical use for ASC is to ignore a “tearout” in the web preventing the guide
from reacting to the subsequent large sensor signal change.
ASC can be configured and enabled separately for each sensor mode. To
prevent unintended ASC activation, it must be enabled for each sensor
mode that is needed using the ASC SETTINGS menu before the ASC ON
button will work.
4.5.1 ASC OFF Disable ASC operation for the selected
sensor mode. This button has no effect if ASC is already off
or has not been configured.
Navigation:
MANUAL / SERVO-CENTER / AUTOMATIC
SETUP
ASC
ASC OFF
4.5.2 ASC ON ASC ON enables ASC processing, if ASC
control has been enabled in the configuration screen for the
active sensor mode.Each sensor mode can be individually
configured with different ASC settings. The availability of
ASC for each sensor mode is among the configurable
settings.
Navigation:
MANUAL / SERVO-CENTER / AUTOMATIC
SETUP
ASC
ASC ON
This icon will be displayed in the status bar when ASC is
enabled.
The ASC icon will change to this when ASC is enabled
and the configured ASC threshold has been triggered. When
ASC is enabled, this icon works in manual mode also which
provides an easy way to view the ASC trigger thresholds.
Note: ASC must be enabled for the active sensor mode
before the ASC ON function will work.