Страница 1: ...Fife 200 Web Guiding System Installation and Service Manual EN MI 1 918 1 C FIFE GUIDING SOLUTIONS...

Страница 2: ......

Страница 3: ...the web guide 3 2 Mounting dimensions 3 4 Wrap styles 3 5 Sensor installation 3 6 SE 47 sensor 3 6 SE 47 sensor position adjustment 3 7 Other Fife sensors 3 7 Installing the operator interface 3 8 Pa...

Страница 4: ...ine or system which does not comply with the machinery directive 2006 42 EC These web guiding systems were designed and manufactured to be installed as Partly Completed Machinery into a machine or par...

Страница 5: ...er guide three parallel inputs per guide and one parallel output per guide The controller controls all the guides through the color touch screen operator interface The controller parallel inputs and o...

Страница 6: ...tent of these operating instructions Any safety instructions on the device The machine manufacturer s specifications All national state and local requirements for installation accident prevention and...

Страница 7: ...rds that may result in bodily injuries or damage to device or material WARNING CAUTION Danger due to crushing Reference to danger of injury caused by crushing WARNING CAUTION Danger due to cutting Ref...

Страница 8: ...uiding System when the machine has been stopped and is secured from being turned on Only perform installation maintenance or repair tasks on the Fife 200 Web Guiding System when there is no electrical...

Страница 9: ...ting parts Appropriate protective guards must be installed by the user according to his use of this product Maintenance and repair WARNING Death or injury can result from unexpected movement Protect a...

Страница 10: ...ent by removing electrical power from the Fife 200 Web Guiding System and the machine into which the Fife 200 Web Guiding System is installed WARNING Danger of injury from crushing Maintenance and rep...

Страница 11: ...g the web guide Mount the guide s in the web path on a rigid support frame using four M8 bolts through the 9 mm 0 35 in diameter holes in the guide support frame Inside type actuator is between mounti...

Страница 12: ...INSTALLATION www maxcessintl com Fife 200 Web Guiding System MI 1 918 1 C Outside type actuator is NOT between mounting surface and guide Figure 2 Guide installation drawing actuator mounting outside...

Страница 13: ...25 0 984 100 3 937 81 mm s 3 189 in s 103 5 4 075 113 5 4 469 205 to 350 8 071 to 13 780 50 1 969 Table 1 Dimensions for actuator mounting inside Refer to Figure 2 for references to dimensions for th...

Страница 14: ...cessintl com Fife 200 Web Guiding System MI 1 918 1 C Wrap styles Allowed wrap styles Mount the guide and thread the web using one of the allowed wrap styles indicated by a checkmark in Figure 3 Figur...

Страница 15: ...olders to secure the fibers in the gland Lift the handle on the cutting tool 5 Insert the gland into the cutting tool as shown in Figure 4 6 Press down firmly on the cutting tool handle to cut off exc...

Страница 16: ...A Once the sensor heads are in the desired location tighten the set screw to prevent the sensor heads from moving A Position adjustment knob B Set screw Figure 6 SE 47 sensor position adjustment Othe...

Страница 17: ...OI FB Panel Mounting Kit 215802 001 OI FB Wall Mounting Kit 216873 001 Panel mount model CAUTION Never place electrical cables under mechanical strain Always provide mechanical support of wiring with...

Страница 18: ...UTION Never place electrical cables under mechanical strain Always provide mechanical support of wiring with either clamps or flexible or rigid conduit 1 Operator interface 2 Operator interface shroud...

Страница 19: ...the system connection overview for sensor types SE 47 SE 11 SE 22 SE 44R and SE 31 Sensor 1 should be sensing the web on Guide 1 The same is true for the other guides and sensors The controller can co...

Страница 20: ...www maxcessintl com Fife 200 Web Guiding System MI 1 918 1 C Installing cables continued Figure 10 shows the system connection overview for sensor type SE 26A Figure 10 System connection overview for...

Страница 21: ...roller end plates 2 Remove the controller cover by pulling up on one side 1 M3 flat head screw 8 ea 2 End plate power entry 3 Controller cover 4 Lock nut for sensor cable bushing 5 Power supply cable...

Страница 22: ...s from the cables in the appropriately marked holes in each of the end plates The lock nut for the power cable bushing is on the bushing Power entry end plate Parallel I O entry end plate Figure 12 Co...

Страница 23: ...ins as shown in the connection diagram in Figure 14 or Figure 15 on the following pages The power motor and OI cable wires are marked with the terminal block pin numbers The sensor cable wires are not...

Страница 24: ...3 15 INSTALLATION www maxcessintl com Fife 200 Web Guiding System MI 1 918 1 C Figure 14 Controller connections for guides and sensor types SE 47 SE 11 SE 22 SE 44R or SE 31...

Страница 25: ...3 16 INSTALLATION www maxcessintl com Fife 200 Web Guiding System MI 1 918 1 C Figure 15 Controller connections for guides and sensor type SE 26A...

Страница 26: ...sure that the outside groove a on the housing cover aligns with the top edge of the base b The threaded opening c is for the screws that secure the end plates to the assembly 2 Attach the end plates t...

Страница 27: ...supply to the power cable The WHITE wire is positive and the BLACK wire is negative 2 Connect the PE of the building or machine to the power cable GREEN wire NOTE The negative power connection BLACK...

Страница 28: ...igure 15 for the controller connections and the parallel I O cable drawing 220601 Note To ensure that a command is properly executed all pertinent inputs for each command must be switched high or low...

Страница 29: ...ervals only Ambient conditions can influence intervals considerably Therefore adjustments to the recommendations must be made accordingly The motor of the Fife 200 guide requires no maintenance Sensor...

Страница 30: ...defgggh Part number C101183 abcddefggghjj abcddefgggh specifies the mechanical attributes of each guide jj specifies the length of the motor and sensor cables in 0 1 meter increments a Guide size roll...

Страница 31: ...bracket 0 None 1 Standard 2 Fine adjustment f Guide direction 1 Left to right 2 Right to left ggg Guide center distance in millimeters 125 to 350 currently h Actuator mounting type 1 Actuator mounting...

Страница 32: ...gital input output port 10 m 32 8 ft Operator interface 20 m 65 6 ft Guide specifications Maximum web tension 49 N 11 lbs Correction speed 60 x 60 61 mm s 2 4 in s 110 x 110 67 mm s 2 6 in s 140 x 140...

Страница 33: ...79 in Length 260 mm 10 24 in Product certifications CE TUV Rheinland of North America to UL61010 1 and CAN CSA C22 2 No 61010 1 and CB Certificate to IEC61010 1 Inputs and outputs Number of guides con...

Страница 34: ...Kelkheim Deutschland Tel 49 6195 7002 0 Fax 49 6195 7002 933 www maxcess eu Maxcess Zhuhai Industrial Automation Equipment Co Ltd 7 Warehousing Factory Hengli Industrial Park 5 Land of Zhuhai Free Tra...

Страница 35: ......

Страница 36: ...sales maxcess eu www maxcess eu CHINA Tel 86 756 881 9398 Fax 86 756 881 9393 info maxcessintl com cn www maxcessintl com cn INDIA Tel 91 22 27602633 Fax 91 22 27602634 india maxcessintl com www maxc...

Отзывы: