6–1
SPECIFICATIONS
www.maxcessintl.com
Fife-200 Web Guiding System
MI 1-918 1 C
General specifications
Operating temperature - 0° to 50° C [32° to 122° F]
Ingress protection class - IP40
RoHS - Compliant
Maximum cable lengths
Power cable - 5 m
[16.4 ft]
Motor cable - 5 m
[16.4 ft]
Sensors - 5 m [16.4 ft]
Digital input/output port - 10 m [32.8 ft]
Operator interface - 20 m [65.6 ft]
Guide specifications
Maximum web tension - 49 N [11 lbs]
Correction speed - 60 x 60
61 mm/s [2.4 in/s]
110 x 110
67 mm/s [2.6 in/s]
140 x 140
76 mm/s [3.0 in/s]
200 x 200
81 mm/s [3.2 in/s]
Correction range - +/- 12 mm [0.47 in]
+/- 10 mm [0.39 in] for 60x60 guide
Dimensions - See Figure 1, Figure 2, Table 1, and Table 2
Weight - 60 x 60
2.5 kg [5.5 lb]
110 x 110
3.6 kg [8.0 lb]
140 x 140
4.4 kg [9.8 lb]
200 x 200
5.7 kg [12.65 lb]
Motor - 24 VDC brushless