i
‐
SHWAK
V4
Inverter
air/water
chillers
and
heat
pumps
with
floor
‐
standing
and
remote
condensing
units
17
8.2.2
Outdoor
unit
It
is
recommended
to
unpack
the
unit
only
with
equipment
positioned
near
the
installation
place,
otherwise
take
special
care
not
to
damage
the
unit
when
handling
it.
Removal
of
the
packing
box:
Cut
the
strap
fasteners.
Remove
the
apparatus
by
lifting
the
packing
upward.
Remove
the
corner
pieces
of
polystyrene
foam.
Remove
the
unit
from
the
pallet
by
unscrewing
the
screws
that
hold
the
feet
to
the
pallet
itself.
When
unloading
and
installing
the
unit,
it
is
highly
recommended
to
avoid
any
sudden
move
in
order
to
protect
the
inner
components.
The
units
can
be
lifted
by
means
of
a
forklift
or,
in
alternative,
of
belts,
being
sure
not
to
damage
the
lateral
panels
and
the
cover.
It
is
important
to
keep
the
unit
horizontal
during
these
operations.
Note:
All
the
pictures
in
this
manual
are
for
explanation
purpose
only.
They
may
be
slightly
different
from
the
unit
you
purchased.
The
actual
shape
shall
prevail.
8.3
LOCATION
AND
MINIMUM
TECHNICAL
CLEARANCES
8.3.1
Indoor
unit
The
installation
must
allow
authorized
personnel
to
operate
in
the
event
of
maintenance,
in
an
easy
manner
respecting
both
the
safety
distances
between
the
units
and
other
apparatus
that
the
technical
spaces
(expressed
in
mm)
indicated
in
the
table:
(*)Recommended
distances
for
lateral
inspection
in
case
of
concealed
installation.
In
case
concealed
installation,
the
inspection
side
is
not
required
and
you
can
keep
up
to
10mm
on
each
side.
MOD.
L1*
L2*
H1
MAR/MARS/MARP/MARPS
300
300
300
Make
sure
that
the
equipment
is
installed
and
protected
from
the
weather
elements
in
a
clean
and
dry
location.
Place
the
unit
on
the
wall.
The
feet
must
be
perfectly
adjusted
in
horizontal
level.
(A)
Level
8.3.2
Outdoor
unit
The
outdoor
units
of
i
‐
SHWAK
V4
series
are
all
designed
for
external
installation:
any
cover
over
the
unit
and
location
near
trees
(even
if
they
partially
cover
the
unit)
is
avoided
in
order
to
allow
the
air
recirculation.
It
is
advisable
to
create
a
proper
basement,
with
a
size
similar
to
unit
foot
‐
print.
Unit
vibration
level
is
very
low:
it
is
advisable
however,
to
fit
a
rigid
rubber
band
between
basement
and
unit
base
‐
frame.
It
is
also
possible
to
install
anti
‐
vibration
supports
(springs
or
rubbers)
to
keep
vibrations
at
a
very
low
level.
Absolute
care
has
to
be
taken
to
ensure
adequate
air
volume
to
the
condenser.
Re
‐
circulation
of
discharge
air
has
to
be
avoided;
failure
to
observe
this
point
will
result
in
poor
performance
or
activation
of
safety
controls.
For
these
reasons
it
is
necessary
to
respect
the
following
clearances
(expressed
in
mm):
MOD.
(Outdoor
units)
A
B
C
D
E
i
‐
SHWAK
V4
06
1500
500
400
400
500
i
‐
SHWAK
V4
08
1500
500
400
400
500
i
‐
SHWAK
V4
10
1500
500
400
400
500
i
‐
SHWAK
V4
12
1500
500
400
400
500
i
‐
SHWAK
V4
14
/
i
‐
SHWAK
V4
14T
1500
500
400
400
500
i
‐
SHWAK
V4
16
/
i
‐
SHWAK
V4
16T
1500
500
400
400
500