39
15
ELECTRIC
DATA
Power
supply
of
the
unit
V/~/Hz
230/1/50*
‐
400/3/50**
Power
supply
of
circulator
and
diverting
valve
(indoor
unit)
V/~/Hz
230/1/50
Outdoor
unit
control
board
circuit
V/~/Hz
12/1/50
Outdoor
fans
power
supply
V/~/Hz
230/1/50
Indoor
unit
control
board
circuit
V/~/Hz
12/1/50
Electric
heaters
power
supply
V/~/Hz
Check
the
power
supply
of
the
unit
*
For
the
single
‐
phase
indoor
units
and
for
outdoor
units
namely:
i
‐
SHWAK
06,
08,
10,
12,
14
and
16.
**
For
the
three
‐
phase
indoor
units
and
for
the
outdoor
units
namely:
i
‐
SHWAK
14T
and
16T.
Note:
Electric
data
may
change
for
updating
the
manual.
It
is
therefore
necessary
to
refer
always
to
the
technical
data
label
attached
on
the
right
‐
side
panel
of
the
unit.
15.1 MAXIMUM POWER CONSUMPTION / MAXIMUM INPUT CURRENT OF THE INDOOR UNITS 06-08
Model
E
‐
heater
MAR1
06
‐
08
MAR3
06
‐
08
MARS1
06
‐
08
MARS3
06
‐
08
NOT
PRESENT
0,13
kW
1,06
A
0,13
kW
1,06
A
0,21
kW
1,66
A
0,21
kW
1,66
A
DHW
heater
of
1,2
kW
1,39
kW
6,54
A
1,47
kW
7,14
A
DHW
heater
of
2
kW
2,13
kW
9,75
A
2,13
kW
3,95
A
2,21
kW
10,35
A
2,21
kW
4,55
A
DHW
heater
of
3
kW
3,13
kW
14,10
A
3,13
kW
5,39
A
3,21
kW
14,70
A
3,21
kW
5,99
A
DHW
heater
of
4,5
kW
4,63
kW
20,62
A
4,63
kW
7,56
A
4,71
kW
21,22
A
4,71
kW
8,16
A
DHW
heaters
of
3+3
kW
6,13
kW
9,73
A
DHW
heaters
of
4,5+3
kW
7,63
kW
11,90
A
DHW
heaters
of
4,5+4,5
kW
9,13
kW
14,06
A
Power
supply
230V/1/50Hz
400V/3P+N+T/50Hz
230V/1/50Hz
400V/3P+N+T/50Hz
Model
E
‐
heater
MARP1
06
‐
08
MARP3
06
‐
08
MARPS1
06
‐
08
MARPS3
06
‐
08
NOT
PRESENT
0,13
kW
1,06
A
0,13
kW
1,06
A
0,21
kW
1,66
A
0,21
kW
1,66
A
DHW
heater
of
1,2
kW
1,39
kW
6,54
A
1,47
kW
7,14
A
Plant
heater
of
1,2
kW
1,39
kW
6,54
A
1,47
kW
7,14
A
DHW
heater
of
1,2
kW
and
plant
side
heater
of
1,2
kW
2,65
kW
12,01
A
2,73
kW
12,61
A
DHW
heater
of
2
kW
2,13
kW
9,75
A
2,13
kW
3,95
A
2,21
kW
10,35
A
2,21
kW
4,55
A
DHW
heater
of
3
kW
3,13
kW
14,10
A
3,13
kW
5,39
A
3,21
kW
14,70
A
3,21
kW
5,99
A
DHW
heater
of
4,5
kW
4,63
kW
20,62
A
4,63
kW
7,56
A
4,71
kW
21,22
A
4,71
kW
8,16
A
Plant
side
heater
of
2
kW
2,13
kW
9,75
A
2,13
kW
3,95
A
2,21
kW
10,35
A
2,21
kW
4,55
A
Plant
side
heater
of
3
kW
3,13
kW
14,10
A
3,13
kW
5,39
A
3,21
kW
14,70
A
3,21
kW
5,99
A
Plant
side
heater
of
4,5
kW
4,63
kW
20,62
A
4,63
kW
7,56
A
4,71
kW
21,22
A
4,71
kW
8,16
A
DHW
heater
2
kW
and
plant
side
heater
2
kW
4,13
kW
18,45
A
4,13
kW
6,84
A
4,21
kW
19,05
A
4,21
kW
7,44
A
DHW
heater
2
kW
and
plant
side
heater
3
kW
5,13
kW
8,28
A
5,21
kW
8,88
A
DHW
heater
2
kW
and
plant
side
heater
4,5
kW
6,63
kW
10,45
A
6,71
kW
11,05
A
DHW
heater
3
kW
and
plant
side
heater
2
kW
5,13
kW
8,28
A
5,21
kW
8,88
A
DHW
heater
of
3
kW
and
plant
side
heater
3
kW
6,13
kW
9,73
A
6,21
kW
10,33
A
DHW
heater
3
kW
and
plant
side
heater
4,5
kW
7,63
kW
11,90
A
7,71
kW
12,50
A
DHW
heaters
of
3+3
kW
6,13
kW
9,73
A
DHW
heaters
3+3
kW
and
plant
side
heater
2
kW
8,13
kW
12,62
A
DHW
heaters
3+3
kW
and
plant
side
heater
3
kW
9,13
kW
14,06
A
DHW
heater
4,5
kW
and
plant
side
heater
2
kW
6,63
kW
10,45
A
6,71
kW
11,05
A
DHW
heater
4,5
kW
and
plant
side
heater
3
kW
7,63
kW
11,90
A
7,71
kW
12,50
A
DHW
heater
4,5
kW
and
plant
side
heater
4,5
kW
9,13
kW
14,06
A
9,21
kW
14,66
A
DHW
heaters
of
4,5+3
kW
7,63
kW
11,90
A
DHW
heaters
of
4,5+4,5
kW
9,13
kW
14,06
A
Power
supply
230V/1/50Hz
400V/3P+N+T/50Hz
230V/1/50Hz
400V/3P+N+T/50Hz
The
electrical
data
of
the
outdoor
and
indoor
units
are
set
to
scale
the
size
of
the
circuit
breakers
and
power
supply
cables.
You
have
to
add
the
input
power
of
the
outdoor
unit
(see
Paragraph
14.2)
and
indoor
unit
depending
on
the
installed
electric
heater
kit.