14
Control panel
MAINTENANCE LED
If it is lit up, send the machine to your dealer or an authorized service facility for inspection. (See page 22)
TEMPERATURE OR ELECTRICAL PROBLEM LED
See the buzzer types in Chapter 6. (See page 21)
The selector switch allows switching among the following operating modes.
The factory default is 2.5-3.0 Normal mode.
•
Before using the control panel, remove the transparent sheet covering it on the shipped ma-
chine.
This machine also offers a power-saving operation Quiet mode that you can select when you want to
suppress the noises accompanying the operation, or when tripping of the circuit breaker is anticipated
during continuous operation. Press the Power-saving switch in Silent mode to turn on this mode.
•
A buzzer sounds with a beep and the LED lights up when the operation switching takes place.
•
The switching is available independent of whether the compressor is in operation or stopped.
•
Even when the circuit breaker tripped or you have disconnected the power plug from the outlet during
operation, status of the last operation is stored in memory.
Operating mode
Pressure control range
Application example
ON pressure
OFF pressure
NORMAL MODE
25 bar
29 bar
Joinery work by MAX
tools,
general-purpose nailers, etc.
HIGH POWER
MODE
30 bar
34 bar
Continuous surface fastening and the
like with MAX
tools.
MAINTENANCE LED
TEMPERATURE OR ELEC-
TRICAL PROBLEM LED
AKHL1230E_UK.fm 14 ページ 2008年12月10日 水曜日 午後6時4分