11. Open the drain cock to discharge all the 

compressed air and water in the air tank.

If you found any abnormalities in the check-
up or inspection prior to the operation, send 
the machine to your dealer or authorized 
service facility for inspection or repair.

Operating Procedure

Before operating the machine, be sure to carry 
out the "Inspection and checkup prior to opera-
tion" described on page 15.

1. Fully open the drain cock and turn the 

power switch on. The buzzer will sound 
with a beep at the same time.

For buzzer sounding patterns, see 
page 21.
After the operation has started, close the 
drain cock tight to increase the pressure.

2. After confirming the operation has 

stopped due to the increased pressure, 
turn the adjustment handle of the pres-
sure-reduction valve to adjust the operat-
ing pressure of the nailer and pneumatic 
tool to the appropriate level. When ad-
justing the pressure, turn the pressure-
reduction valve's adjustment handle 
counterclockwise to set the pressure at a 
level lower than the appropriate value by 
2 bars once. Then proceed to the adjust-
ment while increasing the pressure by 
turning the handle clockwise.

Make sure to start the adjustment at a level 
lower than the appropriate pressure and 
continue the adjustment while increasing 
the pressure from that level upward. If you 
start the adjustment from a level higher 
than the appropriate value, an error results 
between the pressure gauge value and ac-
tually used pressure. (Due to Characteris-
tics of pressure-reduction valve 
respectively)

2 pressure-reduction valves provided on 
this machine allow you to connect MAX 

 and the general-purpose nailer or 

pneumatic tool.
<Pressure-reduction valve H>   Allows 
connection and use of MAX PowerLite 
tools (of operating pressure of 24.5 bars 
maximum)
<Pressure-reduction valve L>   Allows con-
nection and use of the general-purpose 
nailers or pneumatic tools (of operating 
pressure of 8.3 bars maximum)

AKHL1230E_UK.fm  17 ページ  2008年12月10日 水曜日 午後6時4分

Содержание powerlite AKHL1230E

Страница 1: ...UK HIGH PRESSURE COMPRESSOR OPERATING and MAINTENANCE MANUAL BEFORE USING THIS TOOL STUDY THIS MANUAL TO ENSURE SAFETY WARNING AND INSTRUCTIONS KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFEREN...

Страница 2: ...ES 21 7 AUTOMATIC ADJUSTMENT OF OPERATING POWER INVERTER CONTROL 22 8 IN ORDER TO MAINTAIN PERFORMANCE 22 READ THE INSTRUCTION HANDBOOK Before positioning operating or adjusting the compressor read th...

Страница 3: ...PRES SURE AIR HIGH PRESSURE COMPRESSOR IS DESIGNED ONLY FOR MAX POWERLITE NAILERS AND POWERLITE HOSE UNSPECI FIED USAGE WILL CAUSE SERIOUS ACCI DENTS 1 NEVER TOUCH MOVING PARTS Never place your hands...

Страница 4: ...rp edges 12 MAINTAIN COMPRESSOR WITH CARE Follow instructions for lubricating Inspect cords periodically and if damaged have re paired by authorized service facility 13 USE A SAFE EXTENSION CORD In or...

Страница 5: ...p frequently 19 OPERATE COMPRESSOR AT THE RAT ED VOLTAGE Operate the compressor at voltages speci fied on their nameplates If using the com pressor at a higher voltage than the rated voltage it will r...

Страница 6: ...tilt compressor to emp ty accumulated water 28 DO NOT STOP COMPRESSOR BY PULL ING OUT THE PLUG Use the ON OFF switch 29 WHENEVER USING THE HIGH PRESSURE SIDE OF THE MAX POWERLITE COMPRES SOR THE GENUI...

Страница 7: ...er with the air and this could result in an explosion 35 NEVER USE THE TOOL IN AN EXPLO SIVE ATMOSPHERE Sparks from the tool may ignite atmospheric gases dust or other combustible materials 36 BE SURE...

Страница 8: ...asured free field at a distance of 1m ISO2151 Product No AKHL1230E UK Power supply 110V 10 50Hz 1 1 Rated current 13A Motor power 2HP Protective earthing Class I Protective structure IP20 Working temp...

Страница 9: ...protection NOTE The information contained in this Instruc tion Manual is designed to assist you in the safe operation and maintenance of the compressor Some illustrations in this Instruction Manual ma...

Страница 10: ...TY WOODEN CHIPS ETC PLACE 6 INSTALL THE MACHINE IN THE APPRO PRIATE DIRECTION Install it appropriately 7 NEVER INSTALL THE MACHINE IN THE RAIN OR IN A PLACE SPLASHED WITH WATER OR EXPOSED TO HIGH TEMP...

Страница 11: ...CE AN OBJECT ON THE TOP OF THE MACHINE Neglect of this could cause a trouble or break it Do not use the compressor in any place where the temperature is 0 C or less or the ambient temperature exceeds...

Страница 12: ...indicating the set reduction valve pressure 2 gauges General purpose air chuck for regular pressure tools Power plug Power cord Drain cock Pressure reduction valve adjustment handle L Yellow cap Cont...

Страница 13: ...mum on the H side and 8 3 bar maximum on the L side High pressure air chuck for MAX tools It connects the MAX air hose for the tools General purpose air chuck for reg ular pressure tools It connects t...

Страница 14: ...tripping of the circuit breaker is anticipated during continuous operation Press the Power saving switch in Silent mode to turn on this mode A buzzer sounds with a beep and the LED lights up when the...

Страница 15: ...ssure gauge 1 After turning off the machine power switch connect the earthing plug of the power plug to ground and then connect the power plug to the outlet When using an extension cord or drum cord m...

Страница 16: ...ds the operating hours 7 Wait for 5 minutes after the operation is stopped to confirm that there are no ab normal noises or air leakages and that the compressor does not restart 8 Discharge the compre...

Страница 17: ...level When ad justing the pressure turn the pressure reduction valve s adjustment handle counterclockwise to set the pressure at a level lower than the appropriate value by 2 bars once Then proceed t...

Страница 18: ...ng the air hose to the air outlet air chuck 4 Connect the high pressure hose to the high pressure air hose for MAX PowerLite tools to the high pressure air chuck on the H side of the pressure reductio...

Страница 19: ...ns see page 21 2 Connect the power plug to the outlet and turn the power switch on to resume the operation If the motor has sufficiently cooled down the resumed operation may active the pro tective de...

Страница 20: ...s with the power supply or wiring See PROTEC TIVE DEVICE on page 19 Turning on the power switch does not start up the machine Motor vibration is generated 2 Abnormal sounds are generated during operat...

Страница 21: ...p automatically LED remains lighting up with intermittent long beep sounds Pi Pi Pi until power switch is turned off Buzzer sounds Symptom Actions taken A one time short beep sound Pi At powering on W...

Страница 22: ...ply with a power tool When capacity of the main power is 110 V or less or when it is jointly used with another power tool a radical voltage drop results in ducing startup failure The circuit breaker o...

Страница 23: ...g it against solid objects or hitting it can cause deformation cracks or damage to the machine The User is advised not to invite an accident by dropping bumping or hitting the machine 5 Inspect the ma...

Страница 24: ...e without advance notice due to our continuous efforts to improve the quality of our products 4007917 081210 00 00 PRINTED IN JAPAN OSTSTRASSE 22 40211 D SSELDORF GERMANY TEL 49 211 9365300 FAX 49 211...

Отзывы: