background image

matrix 1 led continued

24V

GND

UL ALARM 12V

ALARM RET

RESET

GND

GATE

TAMPER

MAG

LOCK

OPEN

RIGHT

OPEN

LEFT

MAGLOCK

DELAY

PRIMARY

GATE

SAFETY

CENTER

EXIT

OPEN

MAX

GATE SPEED

STOP

CLOSE

ANTI

TAILGATE

CLOSE TIMER

POSITION

RECORDER

ID

PLUG

AUTOMATIC OPEN/CLOSE CONTROLS

BATTERY

BACK-UP MODE

MATRIX 1

PHOTOCELL

EDGE 1

EDGE 2

ID PLUG

ERROR

OPEN

COM

CLOSE

Tamper NO

COM

GND

Tamper IN

OFF

OFF

ON

EXIT

PARTIAL

OPEN

OBD PORT

BLACK BOX

MOTOR MOTION

CENTER

REVERSE SENSITIVITY

MOTOR OVERLOAD

NO LIMIT SWITCH /

CLAMP SLIPPING

MIN

MAX

12VDC

GND

24VDC

GND

MAX

MIN

OFF

SAFETY

LEAVE

OPEN

LEAVE

CLOSED

MADE in USA

OPEN
1 TIME

2Sec

1.5Sec

COM

NC

BATTERY

IN USE

POWER

GATE

STATUS

MOTOR

ON-LINE

LIMIT

SWITCH

ON-LINE

(+)

GND

(-)

PRIMARY

GATE

(+)

GND

(-)

SEC

GATE

 

UL

ENTRAP

PHOTOCELL

GND

STRIKE

GND

KEYP

AD / RDR

GND

FIRE DEPT

GND

MAX OPEN

GND

RADIO SIG.

RADIO GND

OPEN

STOP

CLOSE

COM

GA

TE DISABLE

Matrix 1 LED

Problem Condition

Solution(s) for

Problem Condition

Normal

LED

“PHOTOCELL” LED is ON

“PHOTOCELL” LED is FLASHING

“MOTOR OVERLOAD” LED is ON 

“NO LIMIT SW / CLAMP SLIPPING” LED is ON

“EXIT” LOOP LED is FLASHING or
contstantly ON

“SAFETY” LOOP LED is FLASHING or
contstantly ON

“CENTER” LOOP LED is FLASHING or 
contstantly ON

“GATE DISABLE” LED is ON

“MAG LOCK” LED is FLASHING

“GATE TAMPER” LED is FLASHING

“12VDC” LED is OFF.  “24VDC” LED is OFF

 Jumper between PHOTOCELL and GND is missing or broken (jumper is required if a sensor is not 

 present).

 Sensor on PHOTOCELL input (photocell or edge) may have detected an obstruction while opening or 

 closing gate.

 Photocell on PHOTOCELL input is misaligned with reflector.

 Sensor on PHOTOCELL input (photocell or edge) may not be wired properly, (see     ).

 Sensor is NOT a N.C. monitored sensor that is UL325 2016 compliant.

 Sensor on PHOTOCELL is damaged or malfunctioning.

 Sensor might need to be re-learned.

 Check if gate is binding against catch post or bracket in opened or closed position.

 Check if gate moves manually with low resistance throughout its full range of motion.

 Check if hinges are operational and well greased. 

 Check if operator is positioned properly relative to the gate hinge, (see     ).

 Gate may be too heavy for operator (check manual for maximum gate capacity).

 Check if OPEN / CLOSE limit rings are tightened. 

 Check that clamp is tight on output shaft of operator.

 Loop fault condition: Check if EXIT loop wires are connected into to loop input connector properly.

 Check if loop detector is inserted properly in Matrix 1 slot.

 Set unique loop detector frequency for each loop detector used.

 Loop Detector might be defective. Replace defective loop detector.

  NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).

 Loop fault condition: check if SAFETY loop wires are connected into to loop input connector properly.

 Check if SAFETY loops are wired in series.

 Check if loop detector is inserted properly in Matrix 1 slot.

 Set unique loop detector frequency for each loop detector used.

 Loop Detector might be defective. Replace defective loop detector.

  NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).

 Loop fault condition: check if CENTER loop wires are connected into to loop input connector properly.

 Check if CENTER loops are wired in series.

 Check if loop detector is inserted properly in Matrix 1 slot.

 Set unique loop detector frequency for each loop detector used.

 Loop Detector might be defective. Replace defective loop detector.

  NOTE: RENO loop detector LED’s flash as default, but function normally (ignore the flashing).

 Check if an external device is triggering GATE DISABLE input on Matrix 1. Disconnect devices 

  individually to determine possible false triggering of GATE DISABLE.

 Maglock power is lost. Check if maglock power transformer is wired properly to Matrix 1 or needs to be 

 replaced.

 Gate was manually moved off of its CLOSED position causing Tamper Relay to trigger for few seconds.

 Check for a short in wiring to connected device. DO NOT power external keypads or telephone entry to 

  this port (only use for radio receiver / photocell).

OFF

12

OFF

12

OFF

18

OFF

19

OFF

1

OFF

3

OFF

2

OFF

22

OFF

10

OFF

11

ON

4 or 5

15. ID PLUG ERROR

14. EDGE 2

13. EDGE 1

12. PHOTOCELL

16. UL ENTRAPMENT

17. REVERSE SENSITIVITY

21. POWER

22. GATE DISABLE

8. SECONDARY MOTOR ON-LINE

9. PRIMARY MOTOR ON-LINE

6. SECONDARY LIMIT SWITCH ON-LINE

1. EXIT LOOP

2. CENTER LOOP

3. SAFETY LOOP

7. PRIMARY LIMIT SWITCH ON-LINE

20. BATTERY IN USE

10. MAGLOCK

11. GATE TAMPER

4. 12 VDC

5. 24 VDC

18. MOTOR OVERLOAD
19. NO LIMIT SWITCH

 CLAMP 

SLIPPING

1

8

ID plug 

MUST

 be plugged in.

1400

1400HP

2200

2200HP

FAST

MAX

MEGA

TRON

1400

MA

X

MEGA

TRON

FAST

MA

X

MEGA

TRON

22

0

0

1

5

UL 325 2016 Standard-Megatron Quick Install Rev 10

Содержание Megatron 1400

Страница 1: ...l Commercial Brushless DC Swing Gate Operators Made in USA 14 0 0 H P 2 2 0 0 H P 2 2 0 0 H P P L U S H ig h P r o f ile 14 0 0 2 2 0 0 2 2 0 0 P LU S FA S T FA S T P LU S CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 SAFETY SENSORS REQUIRED Version 10 ...

Страница 2: ...00lbs 15 ft or 1200 lbs 20 ft MAX Megatron 2200 and 2200HP 2200lbs 15 ft or 1500 lbs 20 ft MAX Megatron 2200 PLUS and 2200HP PLUS 2500lbs 15 ft or 1800 lbs 20 ft MAX Megatron FAST 1200lbs 12 ft gate per operator MAX Megatron FAST PLUS 1600lbs 12 ft gate per operator 90 Opening Time MAX Megatron 1400 1400HP 2200 2200HP 2200 PLUS 2200HP PLUS 16 selectable speeds from approximately 11 5 sec to 20 sec...

Страница 3: ... anchors 1 2 MOTOR Power In PWR 24V GND RS 485 RS 485 MATRIX BOARD ALARM BATTERY PACK LIMIT SWITCH MOTOR INPUTS 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OPEN CLOSE CONTROLS BATTERY BACK UP MODE MATRIX 1 PHOTOCELL EDGE 1...

Страница 4: ...T PARTIAL OPEN OBD PORT BLACK BOX MOTOR MOTION CENTER REVERSE SENSITIVITY MOTOR OVERLOAD NO LIMIT SWITCH CLAMP SLIPPING MIN MAX 12VDC GND 24VDC GND MAX MIN OFF SAFETY LEAVE OPEN LEAVE CLOSED MADE in USA OPEN 1 TIME 2Sec 1 5Sec COM NC BA TTERY IN USE POWER GA TE ST A TUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GA TE GND SEC GA TE UL ENTRAP PHOT O CE L L GND ST R I K E GND KE Y PAD RDR GND F ...

Страница 5: ...olt POWER IN POWER SOLAR IN BATTERY IN www max us com Made in USA BATTERY PACK TO MOTOR CONTROLLER PhotoCell Edge UL Entrap 1 2 Limit SW ON LINE MATRIX JOG LEFT JOG RIGHT Jog LT Jog RT GND Edge 1 Edge 2 Photo Cell ERD Motor OverLoad POWER MC 200 Motor Controller 16 15 14 13 12 3 4 5 MAX LED ON Edge Sensitivity ERD CLOSED LIMIT OPEN LIMIT 2 4 V GND UL ALARM 12V ALARM RET RESET GND GA TE T AMPER MAG...

Страница 6: ... tec tion aga inst fire rep lace onl y with the sam e typ e and rati ng of fus e AV ER TIS SE ME NT pou r ne pas com pro me ttre la pro tec tion con tre les risq ues d in cen die utili ser un fus ible de mê me s typ e et car act éris tiqu es nom ina les ON OF F Bat tery E F 1 2 Ba tte ry Vo ltag e Rep lace Bat tery TES T Bat tery Bat tery IN Erro r MA X BC 7 Bat tery Mod ule Ph oto Ce ll Ed ge UL ...

Страница 7: ... 15 14 13 12 3 4 5 M A X LE D ON Ed ge Se ns itiv ity ER D MO TO R Po we r In PWR 24V GND RS 485 RS 485 MA TRI X BO AR D ALA RM BATT ERY PAC K LIMI T SWIT CH MOT OR INPU TS ON OFF Batt ery E F 1 2 Bat tery Vol tag e Rep lace Batt ery TES T Batt ery Batt ery IN Erro r MA X BC 7 Batt ery Mod ule BA TT ER Y IN 24V GND UL ALA RM 12V ALA RM RET RES ET GND GAT E TAM PER MA G LOC K OPE N RIG HT OPE N LEF...

Страница 8: ...limit rings need to be set BEFORE the gate can be cycled or DAMAGE could occur Push and HOLD the JOG LEFT or JOG RIGHT buttons accordingly on the MAX MC 200 motor controller to move the gate release the button to stop gate Re adjust limit ring postions as desired R o t a t e C L O S E D r i n g u n t i l L E D l i g h ts CLOSED LIMIT OPEN LIMIT Arm in CLOSED position Adjust Limit Switches OSED LI ...

Страница 9: ...ON for BOTH MC 200 s whe n du al op erators are us ed 5 Press STO P bu tto n ag ain with in 5 min to learn se ns ors an d en d learn mod e be ep ing stop s Inpu ts are no w MONITORED 2 3 2 3 2 3 A sensor MUST be wired to EDGE 1 or operator WILL NOT function Wire NORMALLY CLOSED N C MONITORED sensors ONLY to each operator s MC 200 when dual operators are used Reversing Edge and or Photo Cell can be...

Страница 10: ...nstall along entire edge of gate Conduit The hinge area may need protection against entrapment MAX 10K mini sensing edge works well in this area OPEN CLOSE direction MC 200 Edge 2 or Photo Cell input Gate Closed Normally CLOSED N C OPENING direction Photocell OPEN CLOSE Sensing Edge on Bottom of Gate If the bottom of gate is 6 or higher above the ground then a 10K sensing edge should be installed ...

Страница 11: ...on Matrix 1 to shut off alarm loops loop detectors 11 ON 1 2 3 4 5 6 7 8 5 Op tim um Se ns Inc rease Se ns De cre ase Se ns DE FL EC TO MET ER PO WER ON No rm al Po we r OF F No Po we r LED INDICA TO RS DE TECT ON De tec t OF F No De tec t 2 Hz Fla sh Dela y Tim ing SW 1 SW 2 Freq ue ncy ON ON Lo w ON OF F Me diu m Lo w OF F ON Me diu m High OF F OF F High SW 4 SW 5 Ou tput B ON ON Pu lse on En tr...

Страница 12: ...ce Dry Contact N O N O NOTE See manual for more info Stop Com External Alarm Reset Button Security Device PRESS to RESET Telephone Entry Dry Contact N O Normal Opening Devices 24V GND UL ALARM 12V ALARM RET RESET GND GATE TAMPER MAG LOCK OPEN RIGHT OPEN LEFT MAGLOCK DELAY PRIMARY GATE SAFETY CENTER EXIT OPEN MAX GATE SPEED STOP CLOSE ANTI TAILGATE CLOSE TIMER POSITION RECORDER ID PLUG AUTOMATIC OP...

Страница 13: ...SA OPEN 1 TIME 2Sec 1 5Sec COM NC BATTERY IN USE POWER GATE STATUS MOTOR ON LINE LIMIT SWITCH ON LINE GND PRIMARY GATE GND SEC GATE UL ENTRAP PHOTOCELL GND STRIKE GND KEYPAD RDR GND FIRE DEPT GND MAX OPEN GND RADIO SIG RADIO GND OPEN STOP CLOSE COM GATE DISABLE P h o t o C e l l E d g e U L E n t r a p 1 2 L i m i t S W O N L I N E M A T R I X J O G L E F T J O G R I G H T J o g L T J o g R T G N ...

Страница 14: ...FO PRI_CIO Communica on Established Fri 07 11 2014 10 57 38 ENTRAP PRI_MC Photo Cell Deac vated Fri 07 11 2014 10 57 34 ENTRAP PRI_MC Photo Cell Ac vated Fri 07 11 2014 10 57 21 INFO Radio Input Deac vated Fri 07 11 2014 10 57 21 INFO Radio Input Ac vated Fri 07 11 2014 10 56 46 WARNING PRI_MC Tamper Reported Fri 07 11 2014 10 56 36 INFO SEC_MC Fully Open Posi on Unknown Fri 07 11 2014 10 56 36 IN...

Страница 15: ...properly If EDGE 2 LED or PHOTOCELL LED is ON on MC 200 If so check entrapment sensor wiring or missing jumper If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch leave Open then battery may be too low and gate is kept OPEN If BATTERY IN USE LED is ON and BATTERY BACK UP MODE switch is set to OPEN 1 TIME then if AC power is lost gate will automatically open 1 time If CLOSE TIMER is OFF the...

Страница 16: ...o to and GND to GND Check wiring between Matrix 1 RS485 gnd and SECONDARY MC 200 RS485 gnd terminals connect to to and GND to GND Check if limit switch box is plugged into PRIMARY MC 200 LIMIT SWITCH input on back and MC 200 is powered ON Check if limit switch box is plugged into SECONDARY MC 200 LIMIT SWITCH input on back and MC 200 is powered ON An entrapment event has occurred check if an entra...

Страница 17: ...is tight on output shaft of operator Loop fault condition Check if EXIT loop wires are connected into to loop input connector properly Check if loop detector is inserted properly in Matrix 1 slot Set unique loop detector frequency for each loop detector used Loop Detector might be defective Replace defective loop detector NOTE RENO loop detector LED s flash as default but function normally ignore ...

Страница 18: ...ate Photocell on EDGE 2 input is misaligned with reflector Sensor is NOT a N C monitored sensor that is UL325 2016 compliant Sensor on EDGE 2 input photocell or edge may not be wired properly see Sensor on EDGE 2 is damaged or malfunctioning Sensor is NOT a N C monitored sensor that is UL325 2016 compliant Jumper between PHOTOCELL and GND is missing or broken jumper is required if a sensor is not ...

Страница 19: ...attery Button Press to show amount of battery power available when using battery power ONLY Battery voltage LEDs will light respectively Replace Battery LED Replace battery when lit BATTERY Plug MUST be plugged into BATTERY IN port Before use POWER SOLAR IN Port MAX Megatron Toroid box connection POWER IN Battery Pack Ports Back of MAX MC 200 motor controller connections ON O FF Battery E F 1 2 Ba...

Страница 20: ... meet the UL 325 2016 standard Type B1 Non Contact sensor entrapment protection device MUST be MONITORED by the gate operator NOTE DO NOT use 10K Resisitor included with photocell NOTE To meet the UL 325 2016 standard Type B1 Non Contact sensor entrapment protection device MUST be MONITORED by the gate operator Installation Steps 1 Set switch to LIGHT ON 2 Wire 12V power to photocell 3 Wire MC 200...

Страница 21: ...N See installation instructions ATTENTION Voir la notice d installation Edge 2 Photo Cell MC 200 PWR 12V MUST be used ONLY power entrapment protection sensors with MC 200 PWR 12V 2 3 A sensor MUST be wired to EDGE 1 or operator WILL NOT function Wire NORMALLY CLOSED N C MONITORED sensors ONLY to each operator s MC 200 when dual operators are used Reversing Edge and or Photo Cell can be wired to AN...

Страница 22: ...he 3 Inputs MC 200 PWR 12V MUST be used to power MONITORED sensors UNUSED inputs MUST remain JUMPERED or fault will occur GN D 1 2 3 GN D 1 2 3 Inputs MUST be LEARNED to MONITOR sensors To LEARN inputs 1 MONITORED Sensors MUST be wired to inputs BEFORE they can be learned Any unused inputs MUST be jumpered 2 Reversing Edge and or Photo Cell can be wired to either input 2 or 3 3 Press and HOLD the ...

Страница 23: ...n receiver 2 Wire 12V power to receiver polarity does not matter 3 Wire MC 200 EDGE 1 to receiver CH 1 P N C Wire MC 200 GND to receiver CH 1 COM 4 Wire MC 200 EDGE 2 to receiver CH 2 P N C Wire MC 200 GND to receiver CH 2 COM 5 Install antenna on receiver 6 Install batteries in transmitters 7 Wire Channel 1 Transmitter to CLOSING Edge ONLY 8 Wire Channel 2 Transmitter to OPENING Edge 9 Program Ch...

Страница 24: ...on River Ave Fountain Valley Ca 92708 Tel 949 699 0220 4009963 CONFORMS TO UL STD 325 UL CLASS I II III IV CERTIFIED TO CAN CSA STD C22 2 NO 247 SAFETY SENSORS REQUIRED Residential Commercial Brushless DC Swing Gate Operators Made in USA Version 10 ...

Отзывы: