LED flashing sequences and transmission behaviour
Before restoring the factory settings of the MAX! Ra-
diator The, first delete the device from the
local MAX! software if you use the radiator thermo-
stat in connection with a MAX! Cube.
• Remove the batteries from the battery compartment.
• Wait 60 seconds.
• Press and hold down the three buttons (Auto/Manu, Boost,
(
) while inserting the batteries.
• Once the factory settings have been restored successfully,
"rES" is displayed.
14
leD
flashIng
sequences
anD
transmIssIon
behavIour
Error code
on the
display
Problem
Solution
Empty
battery
symbol (
)
Battery voltage
too low
Replace batteries
F1
Valve drive slug-
gish
Check the installation; check
whether the pin on the heating
valve is stuck
F2
Actuating range
too wide
Check the fastening of the radia-
tor thermostat
F3
Adjustment
range too small
Check the heating valve; check
whether the valve pin is jammed
F4
Device already
taught-in to
a MAX! Cube
or MAX! Wall
The
Make sure the device is no
longer taught-in to the MAX!
Cube (in the software) or the
MAX! Wall The and
restore the factory settings Then
you can teach-in the device
again.