Configuration menu
value. When the MAX! Window Sensor detects the closing of
the window, all MAX! Radiator Thermostats installed in the
room are immediately reset to their original mode.
Adjust reduced temperature and duration:
A reduced temperature of 12° C and a duration of 15 minutes
is set as default. Both values can be configured individually:
In the MAX! House solution you can configure the set-
tings for the MAX! Radiator The via the MAX!
software.
In the MAX! Room solution you can configure the set-
tings for the MAX! Radiator The via the MAX!
Wall The.
If you use the MAX! Radiator The in the MAX!
Radiator solution, proceed as follows:
• Press the Auto/Manu button longer than 3 seconds.
• Select the menu item "AEr" with the handwheel.
• Confirm with the Boost button.
• Set the reduction temperature with the handwheel and
confirm with the Boost button.
• Set the duration for the reduction temperature with the
handwheel and confirm with the Boost button.
Temperature fall detection without a MAX! Window
Sensor can also be deactivated (by setting the dura-
tion to 0 minutes).