background image

Max Power

5, Via Philips Str, 20900, Monza (MI), Italy
Tel: +39 (0) 39 2001973 - 936, Fax: +39 (0) 39 2004299

Introduction

The purpose of this document is to set out the terms of warranty cover offered in relation to products purchased by the End User from Max
Power or its approved network of resellers.

1. Definitions

Authorized Repair Number:

 The number given by Max Power on reporting a fault with your thruster

Dealer:

 An authorized Max Power sales centre

End User:

 The boat supplied with supplied equipment and the owner thereof

Installer:

 The authorized centre responsible for the installation of your thruster

Manufacturer:

 supplier of the equipment under warranty

Pleasure Craft:

 Vessels used for owner’s personal use that have no commercial use (i.e Charter boats or work boats)

Resellers:

 Max Power approved distributors and dealers

Serial Number:

 Number in upper right hand corner of Warranty document

Supplier:

 The manufacturer (Max Power)

Warranty:

 The terms and conditions that are covered by the manufacturer

2. Period of Coverage

The equipment manufactured by the Supplier is guaranteed to be free from defective workmanship, components and materials under normal
usage conditions for a period of three (3) years from the date of purchase by the End User. This warranty is transferable to subsequent owners
of this equipment during the period of coverage.

3. Warranty Registration

Register your purchase now at 

www.max-power.com

. (NB. proof of purchase must be kept throughout the warranty period)

4. Warranty Terms

If the material is used for anything other than for pleasure craft, the guarantee is limited to a six-month period.

Year 1:

 All factory testing, diagnosis, repairs and replacements are performed at no charge to the End User; All parts and up to two hours of

labour are covered for repairs and replacements conducted in the field.

Year 2 & 3:

 All factory testing, diagnosis, repairs and replacements are performed at no charge to the End User.

This excludes any damage or faults occurring from normal wear and tear on the following items: engine, oil seals, relay contacts(If warranty is
registered within the 3 month period following installation)

5. Warranty Exclusions

Damage due to modifications or installation contrary to published specifications
Cost of hauling the boat
Damage due to repairs performed by an unauthorized service centre
Damage due to lack of normal maintenance services
Damage due to water
Parts replaced due to normal wear and tear
Repairs performed without knowledge of manufacturer (please contact dealer to receive Repair Authorization Number)
Tampering of equipment by the End User
Cost of travel to and from the job site
Cost of economic loss, including injury to any person, damage to property, loss of income or profit, communication, lodging,
inconvenience
Consequential damage due to failure, including those arising from collision with other vessels or objects

6. Procedural Guidelines

PLEASE VIEW THE TROUBLE SHOOTING LIST ON THE MANUAL OF YOUR PRODUCT TO ASCERTAIN OR SOLVE ORIGIN OF PROBLEM PRIOR TO
CONTACTING THE DEALER/INSTALLER

1. Contact your dealer/installer to report the problem.

If you do not know who this is, contact the nearest Max Power distributor
If you are in foreign waters, please contact the nearest Max Power distributor

2. Ensure you have your serial number and model number to hand (top right hand corner of warranty)
3. Dealer/Installer will come to site to decipher the cause of the fault
4. If the cause of fault is due to a manufacturing problem the dealer will contact Max Power to receive Repair Authorization Number.
5. If the problem is due to an installation error please contact your installer.

IF POSSIBLE: PLEASE TAKE PHOTOGRAPHS OF THE THRUSTER TO SHOW PROBLEM

7. Service Centers

Please go online 

www.max-power.com

 to find the authorized service station of your area.

The warranty as outlined above is only applicable to Max Power manufactured thrusters and optional equipment as used in marine pleasure industry. The supplier holds the exclusive right to test the product and

determine whether it is defective

                               1 / 2

Содержание RETRACT R300 Series

Страница 1: ..._ __ __ __ __ __ _ B BU UI IL LT T B BY Y _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ D DE EL LI IV VE ER RE ED D _ __ __ __ __ __ __ __ __ __ _ A copy of this manual must remain on board for con...

Страница 2: ...CT thruster unit 2 Hydraulic equipment 3 Electrical control system 4 Electrical Power system if fitted with Electro pump CHECK LIST FOR THE PROJECT MANAGER It is very important to carefully read the e...

Страница 3: ...allation drawing The following considerations are essential when determining the position of the RETRACT The top of the turbine must be 300 mm below the water line when fully extended In other words t...

Страница 4: ...be moulded into the hull during construction or prefabricated and then laminated onto the hull later METAL HULLS The mounting base may be constructed with the hull or prefabricated and then welded on...

Страница 5: ...ntil connection to hydraulic system Final installation on the mounting base must be made after thoroughly cleaning and then liberally coating both joining surfaces case and base with a good quality ma...

Страница 6: ...son can rotate the eccentric e right or left to raise or lower the locking lever to the position required Replace the bush retaining screw in the nearest convenient hole two holes provided Should the...

Страница 7: ...l rules of accessibility to enable periodic checks and maintenance PRESSURE PIPING All hydraulic high pressure power circuit piping must comply with high pressure standards and have a diameter at leas...

Страница 8: ...ckpressure on the RD drain line will cause damage to the hydraulic motor The reservoir must be flushed after installation DIRECTIONAL CONTROL VALVE BLOCK The directional control valve DCV must be plac...

Страница 9: ...f oil CAUTION Biodegradable and mineral commonly used oils are non compatible and should not be mixed or used together Mixing them will deteriorate certain hydraulic elements If you intend to use a bi...

Страница 10: ...ient size see diagram and should be connected directly from the batteries to the fuse main breaker the power relays and finally the EHP There should be no other equipment or connections in the circuit...

Страница 11: ...Move joystick to port or starboard and check that the up down hydraulic pump is puling the turbine down AFTER LAUNCHING Check for water leaks Switch on the system power at the breaker and repeat the U...

Страница 12: ...O or NF supplied with your system is marked on the valve body and in the control box Adjusting flow limiter 1 Loosen lock nut on bypass flow limiter adjustment screw and open pressure gauge valve both...

Страница 13: ...ding on ambient temperature When finished reverse the above operation move the joystick away from yourself forward or up the green light will extinguish the alarm sounds until the red light illuminate...

Страница 14: ...nd water pump installation to provide extra oil cooling TROUBLESHOOTING GUIDE PROBLEM Thrust stops almost immediately after it has been applied The alarm buzzer comes on and the green light turns off...

Страница 15: ...RETRACT turbine from the DOWN to the UP position Note it can also be used to lower the turbine Lowering the turbine this way has no practical use while at sea but can be useful while on the dry The ma...

Страница 16: ...Check and tighten if necessary the plate fixation bolts 4 apply antifouling paint to the closing plate on the outside on the edges and if desired to the plates inner surface If you find growth on the...

Страница 17: ...MAX POWER PROJECT MANAGER S TEST RESULTS FORM To be filled out and faxed to MAX POWER 17 INSTALLATION MANUAL RETRACT R 300...

Страница 18: ...the hull 2 Is there enough room for general maintenance of the RETRACT and its auxiliary equipment 3 Does the closing plate rest upon a flexible gasket 4 Is the adjustment of the closing plate done i...

Страница 19: ...y terminals Volts With the engine s running and the thruster running either direction 1 Record the charging amps of the alternator s Amps 2 Record the voltage at the remote control box Volts 3 Record...

Страница 20: ...ue continuously until all stop 3 Up down motor energised 4 Up down up valve opened 5 No position detected 5 Alarm sounds continuously 6 Thruster detected as being up 7 All stop motor valve up down val...

Страница 21: ...nimum immersion depth of one full turbine diameter should be respected and the thrusters should be as far forward or aft as possible The thruster must be paralell with the botom of the hull not the wa...

Страница 22: ...ruster Fig 1 Fig 2 Gap Caution this situation would cause damage to the turbine while at sea This gap is essential it should be of at least 5mm In this situation there is still up wards movement posib...

Страница 23: ...e plastic cam e as on diagram Two holes are avalable in the locking bolt Total fine ajustment allows for 10mm of closing plate movement Initial ajustment must be made using the elongated holes in the...

Страница 24: ...MAX POWER Turbine up and locked Turbine down and detected as being down 24 INSTALLATION MANUAL RETRACT R 300...

Страница 25: ...g Switch bar C10 The more bars are on the longer the time delay before port 31 32 energisie Switch bar C11 The more bars are on the longer the delay before port 11 swithes on in NO Programing or off i...

Страница 26: ...P DOWN PUMP RELAY LEFT THRUST VALVE RIGHT THRUST VALVE PRIME MOVER RELAY NEG NEG NEG BYPASS NEG SUPPLY TO CARD POS SUPPLY TO CARD PRIME MOVER NEG PRIME MOVER POS UP DOWN PUMP SUPPLY POS UP DOWN PUMP S...

Страница 27: ...Standard R300 Control Panel 12 19 1 2 18 17 15 16 13 14 POWER POWER Pushing the joy stick up raises the thruster Pushing the joy stick down lowers the thruster Turning the switch to the right renders...

Страница 28: ...F ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF Yachts main equipment breaker bord 4 x 2 mm 2 x 1 mm N 17 18 N 31 32 N 1 8 9 11 N N 21 22 N 1 5 6 N 1 3 4 N 1 2 12 13 14 15 16 17 18 19...

Страница 29: ...elay 1 Power relay 2 Modle R315 4 Modle R321 4 2 x separate cabling Cable sections A B A B 1m Total length in meters A B 3m A B 5m A B 10m Cable section in mm A B 1m A B 3m A B 5m A B 10m Total length...

Страница 30: ...rom hydraulic directional valve to the retract HP thermo plastic hose 1 2 RD Motor drain from retract directly to oil tank LP hose minimum 1 4 or 5 16 RT Return to oil tank from the directional valve...

Страница 31: ...sembly Complete up down unit Control box Hydraulic distribution soft start block Control panel Hydraulic oil reservoir with filtration system Hydraulic pump Clutch PTO adapter 1 2 3 4 5 6 7 8 RETRACT...

Страница 32: ...own unit Control box Hydraulic distribution soft start block Control panel Hydraulic oil reservoir with filtration system Electro hydraulic pump EHP Power relay power fuses 1 2 3 4 5 6 7 8 24V High po...

Страница 33: ...12 4 1 Oil tank 2 Intake strainer 3 Return filter 4 Pump 6 Flow restrictor 8 Bypass 9 Relief valve 10 Pressure guage and valve 11 Directional controle valve 12 Retract motor R300 8 6 33 INSTALLATION...

Страница 34: ...er This excludes any damage or faults occurring from normal wear and tear on the following items engine oil seals relay contacts If warranty is registered within the 3 month period following installat...

Отзывы: