---MAVIX---
MediaRacer® 100 [Preliminar y]
41
4.
During the rebooting process press the space bar to start the
service software. When the main menu of the MediaRacer®
Service Software (Fig 4-1) is displayed, the user can change
default values and configure the MediaRacer® 100 unit
according to his own specifications.
5.
Select option 2 from the MediaRacer® Serv ice Software
main menu. In the “
IP node address”
field define the
IP address of the MediaRacer® 100 unit
according to the
local network requirements. Enter appropriate values in the
other two fields according to the local network requirements.
Return to the main Menu by pressing the [Ctrl] + [P] keys.
6.
Select option 1 from the MediaRacer® Service Software
main menu. Change the default value in the “
Console
I/O
” to
Disable
if you intend to connect other devices to
the MediaRacer® 100 unit COM 1 port instead of the
computer. Verify that the value in the
Boot mode
field is
set to
Application
. If necessary, change values in the other
fields according to your requirements. Return to the Main
Menu by pressing the [ctrl] + [P] keys.
7.
Select option 6 from the MediaRacer® Service Software
main menu to reboot the MediaRacer® 100 unit.
Important
: All setting values that have been changed
during the configuration process will be valid only after the
rebooting of the MediaRacer® 100 unit.
8.
Disconnect the computer from the MediaRacer® 100 unit
COM 1. Connect any other device to this port, as necessary.
9.
Use the Management Software - MediaRacer® Link
Manager Softawre (MLM) or MAVIEW - in order to
operate devices that are connected to the MediaRacer® 100
units.