~150cm
15-25cm
Mounting
LPG detector
~150cm
5-15cm
Mounting naturel
gas detector
LPG is an explosive hydrocarbon gas consisting of butane and propane. It is heavier than
air and sinks to �loor in case of leakage. Therefore, an LPG detector must be mounted
15-25 cm
above �loor and within
1-2 m
horizontally within the range of possible gas
leakage.
Methane (natural gas) is an explosive hydrocarbon gas. It is lighter than air and rises to
ceiling in case of leakage. Therefore, a natural gas detector must be mounted
5-15 cm
below ceiling and
150 cm
horizontally within the range of possible gas leakage.
www.mavili.com.tr
29