1.5 Ambient conditions
Positioning in the electrical box
Follow the instructions in the positioning of the servodrive in the electrical box.
- The drive is natural convection air flow cooled.
- To ensure the drive cooling and make the installation easier for the operator it must be in-
stalled vertically leaving a free space of at least 20 mm (0,78 inch) on each side of the device.
The converter must be mounted vertically on the electrical box. In case you want to mount it
horizontally, remove the cover.
- The electrical box must have suitably filtered air vents.
- Leave the necessary space both above and below the converters.
- Keep the drive from excessive mechanical vibration
Notes during the assembly
Caution: during the wiring of the servodrive in the electrical box, make sure that do not enter
leading wires of copper or iron chips through the slits. Before performing the work cover the
holes with a piece of paper tape. Naturally finished work this tape is removed.
1.6 Ventilation
This servodrive are intended only for use in close locations. Ambient characteristics: operating
temperature from 0 to +40°C. Humidity limit s between 5% to 95% non condensing (Pollution
degree 2 or better).
Supplementary ventilation may be requested in accordance to size. See the table below.
Caution: during the wiring of the servodrive in the electrical box, make sure that do not enter leading
wires of copper or iron chips through the slits. Before performing the work cover the holes with a
piece of paper tape. Naturally finished work this tape is removed.
SIZE
MODEL
2/4
4/8
7/14
10/20
12
N
N
N
N
65
N
N
N
N
100
N
N
N
V
130
N
N
V
N.A
Follow the instructions in the positioning of the servodrive in the electrical box.
- The drive is natural convection air flow cooled.
- To ensure the drive cooling and make the installation easier for the operator it must be installed
vertically leaving a free space of at least 20 mm (0,78 inch) on each side of the device. The converter
must be mounted vertically on the electrical box. In case you want to mount it horizontally, remove the
cover.
- The electrical box must have suitably filtered air vents.
- Leave the necessary space both above and below the converters.
- Keep the drive from excessive mechanical vibration
Conductive mounting
panel (zinc coated)
Dimensions are
expressed in
millimeters.
Cable duct
Cable duct
N = Standard radiator (operating ambient temperature from 0 to 40°C)
V = Standard ra supplementary ventilation (operating ambient temperature from 0 to 45°C)
NA = Not available
This servodrive are intended only for use in close locations. Ambient characteristics: operating tem-
perature from 0 to +40°C. Humidity limit s between 5% to 95% non condensing (Pollution degree 2 or
better).
Supplementary ventilation may be requested in accordance to size. See the table below.